User Manual

Table Of Contents
©
Scania CV AB 2013, Sweden
CAN interface for bodywork
Requirements for CAN communication with the vehicle
11:90-01 Issue 1 en-GB 136 (139)
Source addresses
The bodywork control unit has a non-configurable address and sends messages with
the source address 2E (hex). The source addresses in table 1 are used for messages
sent from the vehicle's internal CAN bus to the external CAN bus via the bodywork
control unit. These addresses must not be used by other control units on the external
network. Incorrect use can lead to conflicts and malfunctions in the external network.
Table 1 shows only the addresses currently in use, but addresses may be added in the
future.
Table 1: Predefined source addresses on the external CAN bus
Name Source address (Hex)
EMS 00
GMS 03
BMS 0B
RET 10
ICL 17
LAS 1D
VIS 1E
COO 27
BWS 2E
SMS 2F
APS 30
TCO EE