CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 15 (139)
Scania Bodywork Control Message 2
Identifier: 0C FF F9 XX
Transmission interval: 100 ms
Byte Bit Length Explanation State Resolution Limits Note
118Message configuration version 02h 0 to 250 A
212Increased idle speed switch 1 (ISSW1) B
ISSW1 not demanded 00
ISSW1 demanded 01
Error indicator 10
Not available or not installed 11
32Increased idle speed switch 2 (ISSW2) C
ISSW2 not demanded 00
ISSW2 demanded 01
Error indicator 10
Not available or not installed 11
5..8 Not defined
312Second vehicle speed limiter
Speed limit not requested 00
Speed limit requested 01
Error indicator 10
Not available or not installed 11
3..4 Not defined
52Torque limit 1
Torque limit 1 not requested 00
Torque limit 1 requested 01
Error indicator 10