User Manual

Table Of Contents
©
Scania CV AB 2013, Sweden
CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 22 (139)
A: Enter the correct version of the message here. This is version 1.
B: Signal which activates indicator lamps for bodywork functions or sound in the in-
strument cluster.
C: Part of UF 117 Third speed limiter.
Driver information requested 01
Error indicator 10
Not available or not installed 11
5116Requested vehicle speed limit 0.00390625 0 - 250.996 C
No request 0xFB00
Error indicator 0xFExx
Not available or not installed 0xFFxx
7..8 Not defined
Byte Bit Length Explanation State Resolution Limits Note