CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 37 (139)
Cab Illumination Message
Identifier: 18 D0 FF 17
Transmission interval: 100 ms.
Always sent from BWS.
Byte Bit Length Explanation State Resolution Limits Note
118Requested illumination percentage 0.4 % 0-100 %
Error FEh
Not available FFh
2..8 Not defined