User Manual

Table Of Contents
©
Scania CV AB 2013, Sweden
CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 47 (139)
Coordinator General Information 2
Identifier: 0C FF AF 27
Transmission interval: 1,000 ms
Always sent from BWS.
Byte Bit Length Explanation State Resolution Limits Note
1 1..8 Not defined
212Low engine coolant water level
Not low engine coolant water level 00
Low engine coolant water level 01
Error 10
Not available 11
3..8 Not defined
3..8 Not defined