PRE INSTALLATION GUIDE FÖRINSTALLATIONSGUIDE ANLEITUNG VOR DER INSTALLATION 預安裝指南 FOR PRO Scanomat Download Center Scanomat Connection Diagram Scanomat Architect Pack (2D/3D Files) For TopBrewer Pro Version: 4.
CONTENTS » » » » » Introduction Product Matrix: Choose your setup Products Overview Space requirements: Basic Installation Space requirements: Extended Installation CARPENTER & VENTILATION » » » » » » » » » » » » 3 4 5 6 7 8 Basic Installations Example 1 - Pro Fridge A2 9 Example 2 - Pro Fridge A3 10 Example 3 - Duct rediverted 11 Extended / Special Installations Example 1 - with cold water 12 Example 2 - with two Pro 1
Introduction The operation of a TopBrewer Pro coffee system. The TopBrewer Pro consists of a main unit, the coffee machine, the ”swan neck” or tap that is installed through the tabletop and is height adjustable through the mounting bracket, a drained drip tray and a ventilation kit for the toe kick base. Additionally we offer optional accessories that are installed along side of the TopBrewer.
Product Matrix Choose your setup Configuration Choices Cabinet Layout LESS THAN 590 MM DEPTH ALLOWS FOR MORE THAN 590 MM DEPTH HIDDEN OR BEHIND THE WALL WITH WATER PAGE 14 PAGE 14 PAGE 16 WITHOUT WATER PAGE 12 PAGE 11 PAGE 16 WITH HOT CHOCOLATE N/A PAGE 11 PAGE 16 WITH WATER AND HOT CHOCOLATE PAGE 12 PAGE 14 PAGE 16
Fridges Water coolers Products Overview Racks TB A3 A2 A1 B1 C2 C1 A4 * OPTIONALLY WITH CO2 UNIT DETAILS TopBrewer Pro ICE-Bank (A1)* Pro-fridge (A2) Pro-fridge Tall (A3) Cooler 45 (B1)* Pro-Fridge BiB (A4) Slimrack (C1) Chocolate rack (C2) Installation Dimensions (WxDxH) 224 x 560 x 667 mm 236 x 569 x 428.
Space requirements Basic Installation 1 CLEARANCE HEIGHT NEEDED FOR INSTALLATION OF SWAN NECK MIN 500 MM A 600 MM CABINET RECOMMENDED MIN. TOTAL WIDTH 580 MM Compact ventilation 294 MM 680 MM MINIMUM 750 MM RECOMMENDED C2* A2 min. 90 mm Recommended depth 610 mm Minimum 600 mm Always allow min. 40 mm clearance Always allow min.
Space requirements Basic Installation 2 A 700 MM CABINET RECOMMENDED CLEARANCE HEIGHT NEEDED FOR INSTALLATION OF SWAN NECK MIN 500 MM MIN. TOTAL WIDTH 595 MM Center ventilation 294 MM 680 MM MINIMUM 750 MM RECOMMENDED C2* A2 min. 90 mm Recommended depth 650 mm Minimum 600 mm Always allow min. 40 mm clearance Always allow min.
Space requirements Extended Installation 1 A 700 MM CABINET RECOMMENDED MIN. TOTAL WIDTH 580 MM CLEARANCE HEIGHT NEEDED FOR INSTALLATION OF SWAN NECK MIN 500 MM Compact ventilation 470 MM RECOMMENDED MIN. TOTAL WIDTH 400 MM 294 MM 680 MM MINIMUM 750 MM RECOMMENDED C2* C300 A2 B1 min. 90 mm A1 : 569 mm A2: 600 mm A3: 534 mm A4: 560 mm Always allow min. 40 mm clearance Always allow min.
Space requirements Extended Installation 2 Center ventilation CLEARANCE HEIGHT NEEDED FOR INSTALLATION OF SWAN NECK MIN 500 MM A 700 MM CABINET RECOMMENDED MIN. TOTAL WIDTH 580 MM 470 MM RECOMMENDED MIN. TOTAL WIDTH 400 MM 294 MM 680 MM MINIMUM 750 MM RECOMMENDED C2* C300 A2 B1 min. 90 mm A1 : 569 mm A2: 600 mm A3: 534 mm A4: 560 mm Always allow min. 40 mm clearance Always allow min. 60 mm clearance Always allow min.
CARPENTER SNICKARE ZIMMERMANN 木匠 10
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Basic Installation Example 1 Using: TB + A2 or A1 + C2* Clearance min: 500mm Ventilation pipe through toekick using SKU 4302774 Max 444 mm Air Inlet Dimensions, minimum 78 cm2 H: 30mm OR 260 mm 130mm 130mm Recommended: 690mm 330 mm ø100 mm 490 mm A2 min.
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Basic Installation Example 2 Using: TB + A3 Clearance min: 500mm Ventilation pipe through toekick using SKU 4302774 Max 444 mm Air Inlet Dimensions, minimum 78 cm2 H: 30mm OR 260 mm 130mm 130mm AC Fan min.
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Basic Installation Example 3 Air Inlet Dimensions, minimum 78 cm2 H: 30mm 130mm 130mm Recommended: 690mm 260 mm OR TB min. 600 mm Max 444 mm Using: TB + A1, A2 or A3 + C2* Clearance min: 500mm Ventilation pipe through toekick using SKU 4302774 + flex tube A2 Min.
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Extended Installation Example 1 Using: TB + A2 or A3 + B1 + C2* Air Inlet Dimensions, minimum 78 cm2 Clearance min: 500mm 260 mm H: 30mm 130mm 130mm ø100 mm C2* A2 TB C300 min.
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Extended Installation Example 2 Max 444 mm Using: TB + A2 or A3 + TB Clearance min: 500mm Two Pro’s sharing a single Pro-fridge Air Inlet Dimensions, minimum 78 cm2 260 mm H: 30mm OR 130mm 130mm 500 mm Recommended: 600mm ø100 mm AC Fan 71 mm Funnels hot air out
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · AIR EXHAUST SHOULD REMAIN UNOBSTRUCTED Carpentry preperations Special Installation Example 3 Special example of behind-the-wall utilizations Using: TB + A1, A2 or A1 + C2* Using Bluetooth external antenna, length 1,5 m. SKU 4302690 CLICK HERE TO SEE EXAMPLE Hoses to faucet is led through wall. Maximum length, 1,5 m.
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · Measurements for top mounted iPad Holder Swan Neck & Driptrays Overview of positioning 144 mm 29 4m m ø32 160 -25 0m m m 0m 0 3 0 5 2 17 · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER ·
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · TopBrewer topmounted iPad Holder + Lock Optional lock ø9 52,9 mm 160-250 mm 294 mm 200-250 mm 144 mm 18 · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER ·
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · BOXIT (Table Mount or Wall-Mount options) 160-250 mm ø20 294 mm 200-250 mm 144 mm 19 · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER ·
· CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · CARPENTER · Cut out sheet - Swan neck + Driptray NOTE that this driptray is best used for water resistent tabletops such as Granite, Marble or Corian. If wood, make sure poures are completely sealed.
ELECTRIC ELEKTRISK ELEKTRISCH 電的 21
· ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · ELECTRICAL · Electrical Requirements IMPORTANT Electrical Installations to be placed here 4 All electrical must be kept within boundary X Single phase 230V, 10 amp Plug point US & Canada: Single phase 115V, 60 Hz, 10 Amp Fridge, Optional Cooler, Ventilation & iPad Charger Safety switch for machine main power S 3 phase, 400V 10-1
PLUMBING VVS KLEMPNERARBEITEN 水暖 23
· PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · Plumbing - adjacent cabinet Drainline from driptray 1m Fridge waste water 5 cm Drainpump from machine Filters Main Water w/ shutoff valve Filters are chosen based on the projected usage pattern of the machine. Distance of installation relative to the machine are unlimited. An example of the capacity is listed below.
· PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · PLUMBING · Plumbing - same cabinet U-Pipe is required Drainline from driptray Fridge waste water 1m 5 cm Drainpump from machine Main Water w/ shutoff valve *Drainline from Chocolate Rack Filters Filters are chosen based on the projected usage pattern of the machine. Distance of installation relative to the machine are unlimited.
For more information & questions to your installation, contact us on the below channels Tecnical / Architect Support E-mail: support@scanomat.dk Chat: www.scanomat.com International: +454918180 Denmark: +4549181212 Sweden: +46 (0)774 41 0000 Norway: +47 22662210 UK: architect@scanomat.co.uk Locate Dealer: scanomat.com/services/partners For TopBrewer Pro Version: 4.