Figure WC-1HP.08 - WayCool® Control Switch 
The WayCool® WC-1HP control switch is mounted on the outside of one frame leg (see cover fig). 
It has the following positions: 
OFF - Power is off to the blower motor and the pump motor. 
LOW VENT - The blower runs at low speed and the pump is OFF. 
HIGH VENT - The blower runs at high speed and the pump is OFF. Use this setting to quickly dry 
the cooling pads for removal and cleaning. 
LOW COOL - The blower runs at low speed and the pump is on. Use this setting for low cooling 
loads. 
HIGH COOL - The blower runs at high speed and the pump is on. Use this setting for maximum 
cooling. 
PUMP ONLY - Pump is on and the blower is OFF. Use this setting during startup to first saturate 
the cooling pads, then switch to LOW COOL or HIGH COOL to begin cooling. 