Datasheet

Common-mode Suppression Chokes
n Rated currents up to 5A
n Broadband attenuation characteristics
n Low magnetic leakage flux
n UL rated materials
n RoHS compliant
Technical specifications
Maximum continuous operating voltage: 250VAC @ 50°C
Operating frequency: dc to 400Hz @ 50°C
Rated currents: 0.3 to 5A
Overcurrent: 1.5x I
nominal
for 1 minute, once per hour
High potential test voltage
winding-to-winding @ 25°C: 3000VAC, 60 sec, guaranteed
2000V, 50Hz, 2 sec, factory test
Temperature range (operation and storage): -25°C to +100°C (25/100/21)
Flammability corresponding to: UL 94V-0
Test conditions
Measuring frequency: 10kHz; 5mA < 16μH;
500μA > 16μH < 160μH;
50μA > 160μH > 16mH;
50mV > 16mH < 160mH
Inductance tolerance ±30%
Resistance: Tolerance max. ±15% @ 25°C; ≤ 20mΩ, 1A;
> 20mΩ ≤ 200mΩ, 100mA; > 200mΩ ≤ 2V, 10mA
Electrical characteristics: @ 25°C ±2°C
Typical applications
Common-mode suppression chokes are
mainly used to filter noise on AC power lines.
Noise on commercial power lines could enter
the equipment and disturb the proper
function. Noise generated by the equipment
for example from switch mode power
supplies need to be filtered and the spread of
such generated noise need to be suppressed.
Common-mode suppression chokes together
with line bypass capacitors building an AC
EMI suppression filter device.
n Rated currents up to 5A.
n Compact and light weight.
n Low magnetic leakage flux.
n Sectional winding.
n Standard foot print.
n Broad range of available inductances and
current ratings.
n Custom-specific versions.
n Schaffner offers you also EMI measure-
ment service to verify that your design will
pass the required safety standards.
n Input filters for switch mode power
supplies
n Filters to reduce leaking noise
n TVs, VCRs, multimedia and audio
equipment
n Office automation, communications and
other electronic devices
n Electric ballast
n AC/AC converters
Features and benefits
Typical electrical schematic
1
4
2
3
RFI suppression Chokes
EV/EH series