Datasheet

Features and benefits
FN 2010 filters are designed for easy
and fast chassis mounting.
FN 2010 filters are also available as B
versions without Y-capacitors for
medical applications as well as A
version with low capacitance for safety
critical applications with necessity for
low leakage currents.
All filters provide a general purpose
conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal
behavior.
FN 2010 filters can be used to cover a
broad range of usage and they offer a
good size/amperage ratio.
FN 2010 filters are also available as
two-stage filters (FN 2060, FN 2070
series) for more noisy environment.
Various terminal options allow you to
select the desired connection style.
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Office automation equipment
Datacom equipment
Single-Phase Filters
FN 2010
General Purpose EMI Filter
Rated currents from 1 to 60A
General purpose filtering
performance
Optional medical versions (B type)
Optional safety versions (A type)
Approvals
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1 to 60 A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec
P –> PE 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec (1 to 20A types)
P –> N 1100VDC for 2 sec (30 and 60A
types)
Temperature range (operation and
storage):
-25°C to +100°C (25/100/21)
Flammability corresponding to: UL 94V-2 or better
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN
60939
MTBF @ 40°C/230V (Mil-HB-217F): 1,250,000 hours
3,200,000 hours (B types)
Typical electrical schematic

Summary of content (5 pages)