Datasheet

Versatile Filtered Power Entry Module
Approvalsn Rated currents up to 6A
n Single or dual-fuse holder
n Fuses Ø6.3 x 32mm or Ø5 x 20mm
n 2-pole rocker switch
n General purpose application
n Optional medical versions (B type)
Typical applications
The FN 380 power entry module combines an
IEC inlet, a mains filter with asingle or dual-
fuse holder and a 2-pole rocker switch.
Choosing FN 380 product line brings you the
rapid availability of a standard filter associated
with the necessary safety acceptances.
Standard IEC connector filters are a practi-
cal solution helping you to pass EMI system
approval in a short time. A wide selection on
amperage ratings, fuse options, mounting
possibilities and filters for medical applications
are designed to offer you the desired solution.
n Good conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
n Rear/front or snap-in mounting.
n Single or dual-fuse holder.
n USA Ø6.3 x 32mm or EU Ø5 x 20mm fuses.
n 2-pole rocker switch.
n Custom-specific versions are available on
request.
n Portable electrical and electronic
equipment
n Consumer goods
n EDP and office equipment
n Single-phase power supplies, switch-mode
power supplies
n Test and measurement equipment
n Medical equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: 50 to 400Hz
Rated currents: 2 to 6A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec (standard types)
P –> PE 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 550,000 hours
Rocker switch description:
Function: 2-pole, dark not illuminated
Marking I - 0
Electrical specifications: Inrush current 51A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life: 50,000 cycles
Switch ratings:
USA (UL): 6A, 125VAC; 4A, 250VAC; 1/10HP
Canada (CSA): 6A, 125VAC; 4A, 250VAC; 1/10HP
Europe (ENEC): 6A (4A), 250VAC*
* Value in () relates to the inductive current charge: cos g = 0.65
Typical electrical schematic
N
PE
P
Line
Cx 2xL 2xCy
Load
M K H
L J G
IEC Inlet Filters