Datasheet
* Value in () relates to the induc tive c urrent charge: cosφ = 0.65
The FN 390 power entry module combines
an IEC inlet, mains filter with single or
dual-fuse holder, voltage selector and 2-
pole rocker switch. Choosing FN 390
product line brings you the rapid
availability of a standard filter associated
with the necessary safety acceptances.
Standard IEC connector filters are a
practical solution helping you to pass EMI
system approval in a short time. Multiple
options designed to offer you the desired
solution.
Features and benefits
High conducted attenuation
performance, based on chokes with
high saturation resistance and
excellent thermal behavior.
Rear or front mounting.
Single or dual-fuse holder.
USA Ø6.3 x 32mm or EU Ø5 x 20mm
fuses.
2-pole rocker switch.
Voltage selector 110-120V / 220-240V.
Custom-specific versions are available
on request.
Typical applications
Portable electrical and electronic
equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-
mode power supplies
Test and measurement equipment
IEC Inlet Filters
FN 390
Versatile Filtered Power Entry
Module
Rated currents up to 10A
For one or two fuses
Fuses Ø6.3 x 32mm or Ø5 x 20mm
2-pole rocker switch
Voltage selector
Optional earth line choke (E type)
Approvals
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: 50 to 400Hz
Rated currents: 1 to 10 A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and
storage):
-25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN
60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 2,200,000 hours
Voltage selector description:
Function: Series/parallel
Voltage marking:
Series: 110-120V
Parallel: 220-240V
Rocker switch description:
Function: 2-pole, dark not illuminated
Marking I - 0
Electrical specifications: Inrush current 51A
6,000 on-off operations according to UL
1054, TV 5
10,000 on-off operations according to ENEC
Mechanical life: 50,000 cycles
Switch ratings:
USA (UL) and Canada (C-UL): 10A, 125VAC; 10A, 250VAC; 1/3HP
Europe (ENEC): 10A (4A), 250VAC*
Typical electrical schematic