Datasheet
2 EMC/EMI Products Schaffner Group Datasheets 2018
Filter selection table
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [μF] [nF] [kΩ]
[g]
FN 2030-1-.. 1 (1.1) 0.31 (0.18) 20 0.22 2.2 1000 -06 -07 58
FN 2030-3-.. 3 (3.4) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 87
FN 2030-4-.. 4 (4.5) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 92
FN 2030-6-.. 6 (6.7) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 100
FN 2030-8-.. 8 (8.9) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 170
FN 2030-10-.. 10 (11.2) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 196
FN 2030-12-.. 12 (13.4) 0.79 (0.45) 4 1.0 10 330 -06 -07 185
FN 2030-16-.. 16 (17.9) 0.79 (0.45) 4 1.0 10 330 -06 -07 225
FN 2030-20-.. 20 (22.4) 0.79 (0.45) 4 1.0 10 330 -06 -08 285
FN 2030-30-08 30 (33.5) 0.79 (0.45) 2 1.0 10 330 -08 326
FN 2030 A-1-.. 1 (1.1) 0.07 (0.04) 20 0.22 0.47 1000 -06 -07 58
FN 2030 A-3-.. 3 (3.4) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 87
FN 2030 A-4-.. 4 (4.5) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 92
FN 2030 A-6-.. 6 (6.7) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 100
FN 2030 A-8-.. 8 (8.9) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 170
FN 2030 A-10-.. 10 (11.2) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 196
FN 2030 A-12-.. 12 (13.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 185
FN 2030 A-16-.. 16 (17.9) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 225
FN 2030 A-20-.. 20 (22.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -08 285
FN 2030 A-30-08 30 (33.5) 0.07 (0.04) 2 1.0 0.47 330 -08 326
FN 2030 B-1-.. 1 (1.1) 0.00 20 0.22 1000 -06 -07 58
FN 2030 B-3-.. 3 (3.4) 0.00 14 0.33 1000 -06 -07 87
FN 2030 B-4-.. 4 (4.5) 0.00 14 0.33 1000 -06 -07 92
FN 2030 B-6-.. 6 (6.7) 0.00 8 0.47 680 -06 -07 100
FN 2030 B-8-.. 8 (8.9) 0.00 8 0.47 680 -06 -07 170
FN 2030 B-10-.. 10 (11.2) 0.00 8.45 0.47 680 -06 -07 196
FN 2030 B-12-.. 12 (13.4) 0.00 4 1.0 330 -06 -07 185
FN 2030 B-16-.. 16 (17.9) 0.00 4 1.0 330 -06 -07 225
FN 2030 B-20-.. 20 (22.4) 0.00 4 1.0 330 -06 -08 285
FN 2030 B-30-08 30 (33.5) 0.00 2 1.0 330 -08 326
Enhanced performance
FN 2030 N1-1-06 1 (1.1) 5.34 (3.08) 20 0.22 68 1000 -06 65
FN 2030 M-3-06 3 (3.4) 3.69 (2.28) 14 0.33 47 1000 -06 110
FN 2030 M-4-06 4 (4.5) 3.69 (2.28) 14 0.33 47 1000 -06 110
FN 2030 M-6-06 6 (6.7) 3.69 (2.28) 8 0.47 47 680 -06 120
FN 2030 N1-8-06 8 (8.9) 5.34 (3.08) 8 0.47 68 3680 -06 200
FN 2030 N1-10-06 10 (11.2) 5.34 (3.08) 8 0.47 68 680 -06 200
FN 2030 N1-12-06 12 (13.4) 5.34 (3.08) 4 1.0 68 330 -06 210
FN 2030 M-16-06 16 (17.9) 3.69 (2.28) 4 1.0 47 330 -06 265
FN 2030 M-20-.. 20 (22.4) 3.69 (2.28) 4 1.0 47 330 -06 -08 326
FN 2030 M-30-08 30 (33.5) 3.69 (2.28) 2 1.0 47 330 -08 346
* To compile a complete part number, please replace the -.. with the required I/O connection style. For surge pulse protection, please add Z (e.g. FN 2030Z-10-06, FN 2030BZ-20-08).
The different letters code the used Cy values in the filter type (A = 0.47nF; M = 47nF; N1 = 47nF)
** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Leakage current
for DC application is 0 mA