Datasheet
DATASHEET
IEC Inlet Filters FN 9280
Ultra Compact and Versatile Filtered Power Entry Module
Single stage filter
Ultra compact design
Rated currents up to 10 A
dual-fuse holder
Fuses Ø5x20 mm
2-pole rocker switch
Good attenuation performance
Faston or spring cage terminals
Check the video of our IEC Inlet
Filters FN 9280 and FN 9290 on
Youtube!
Performance indicators
Technical specifications
Mechanical life
50,000 cycles
High potential test voltage
P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 760 VAC for 2 sec
MTBF @ 40°C/230 V (Mil-HB-217F)
>1,000,000 hours
Temperature range (operation and storage)
– 25°C to +85°C (25/85/21)
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, EN 60939, EN 60950, EN
60601-1, UL 544, EN 60320
Flammability corresponding to
UL 94 V-2 or better
Maximum continuous operating voltage
250 VAC, 50/60 Hz
Rated currents
1 to 10 A @ 40°C max.
Operating frequency
DC to 400 Hz
Switch ratings
USA (UL) and Canada (C-UL)
10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP
Europe (ENEC)
10 A (4 A), 250 VAC**
Electrical specifications
Inrush current 82 A
6,000 on-off operations according to UL 1054
10,000 on-off operations according to ENEC
Leakage current
Standard: <500 uA at 250 VAC/50 Hz
Medical: <5 uA at 250 VAC/50 Hz
Protection category
IP 40 according to IEC 60529 (front side)
Fuse holder
2 fuses (Ø5 x 20 mm) max. 250 V
Terminals
IP 20 spring cage safe against finger touch
Spring cage wire range
0.2 –1.5 mm2 / 24 –16 AWG single or flexible wire
Rocker switch
2-pole, dark not illuminated, Marking I - 0
* 10 A version is 8 A UL and CSA approved
** Value in () relates to the inductive current charge: cos γ = 0.65
Approvals
(CQC except HI-types; Patent US 20110227692/US
8766761; CN ZL201080069589.0)
Choosing FN 9280/90 product line brings you the
rapid availability of a standard filter associated with
the necessary safety acceptances and a high
attenuation performance. For higher attenuation
performance the FN 9290 family with a dual stage
filter and identical panel cut-out can be used.
Standard IEC connector filters are a practical solution
to pass EMI system approval in a short time. A wide
selection of amperage ratings, mounting possibilities
and also filters for medical applications are designed
to offer you the best solution.
Features and benefits
Good conducted attenuation performance, based
on chokes with high saturation resistance and
excellent thermal behavior
Deep-drawn iron-sheet housing for best possible
shielding against magnetic fields
Rear/front flange mounting or snap-in versions
Dual and additional spare fuse holder
2-pole rocker switch
Faston or spring cage terminals
Medical version (B Type) according IEC/EN 60601-1
All versions according IEC/EN 62368-1
Typical applications
Portable electrical and electronic equipment
Consumer goods
EDP and office equipment
Single-phase and switch-mode power supplies
Test and measurement equipment
Medical electrical devices (MD) and
In-Vitro
-
Diagnostics (IVD) equipment
Audio/Video, information and communication
technologies
Typical electrical schematic