Have any damage to your equipment
repaired by a specialist.
If the power cable for this equipment
is damaged, it must be replaced by
the manufacturer, a customer service
agent of the same or a similarly quali-

Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.

cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Before any work on the equipment, dur-
ing work breaks and in the case of non-
use, remove the plug from the socket.
The cross-section of mains connec-
tion lines must be no smaller than rub-
ber hose lines with the designation
H07RN-F. The line must be 10 m long.
The strand cross-section of the exten-
sion cable must be at least 1.5 mm
2
.
Inside the pump, lubricants are used
which may contaminate the liquids being
discharged in case of any improper oper-
ation or damage of the device.
Warning! This electric tool generates
    -
       -
sive medical implants under certain con-
ditions. In order to prevent the risk of se-
rious or deadly injuries, we recommend
that persons with medical implants con-
sult with their physician and the manufac-
turer of the medical implant prior to oper-
ating the electric tool.
Electrical safety:
After erection, the mains plug must be
freely accessible when the equipment
is in operation.
Before operating your new pump, have
a specialist check:
The earthing, the protective multi-
ple earthing; the residual current cir-
cuit breaking must be compliant with
the safety regulations of the energy
supply company and function with-
out fault,
The protection of the electrical plug
connections from the wet.
        
plug connections in an area that is

Ensure that the mains voltage matches

The electrical installation shall be ac-
cording to national wiring rules.
Connect the equipment only to a sock-
et with a residual current protection de-
vice (residual current circuit breaker)
with a rated current of not more than 30
mA; minimum fuse 6 amperes.
Before each use, check the equipment,
cable and plug for damage. Defective
cables are not to be repaired, but rather
replaced by new ones.