The motor is automatical/y switched off in the event of
an overload. The motor can be switched on again after a
cooling down period that can vary.
Three-phase motor
The mains voltage must be between 380 and 420 V
/ 50 Hz.
The connection to the mains and the connection cable
must have ve leads (3 P + N + PE).
Extension cables must have a cross-section of at least
1.5 mm
2
.
Warning:
The drill press must not be operated in the open air. The
machine must have an earth Gable to protect the opera-
tor from etectrical shocks.
12. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in this
packaging can be reused or recycled. The equipment
and its accessories are made of various types of mate-
rial, such as metal and plastic. Never place defective
equipment in your household refuse. The equipment
should be taken to a suitable collection center for
proper disposal. If you do not know the whereabouts
of such a collection point, you should ask in your local
council ofces.
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles.
Wear parts*: Carbon brushes, v-belt, drill
* Not necessarily included in the scope of delivery!
10. Storage/Transport
Store the equipment and accessories out of children’s
reach in a dark and dry place at above freezing temper-
ature. The ideal storage temperature is between 5 and
30 °C. Store the electric tool in its original packaging.
m Attention! Unplug the machine!
The appliance must unconditionally be secured against
falling or turning down during transport.
The appliance can be lifted on the left and right grinding
wheel / belt sander cover. Power cable, exible lamp
shaft etc. should not be used for transport purpose.
11. Electrical connection
The installed electric motor is completely wired ready tor
operation. The customer‘s connection to the power sup-
ply system, and any extension cables that may be used,
must conform with local regulations.
Defective electrical connection cables
Electrical connection cables offen suffer insulation dar-
nage.
Possible causes are:
Punch points when connection cables are run through
window or door gaps.
Kinks resulting from incorrect attachment or laying of
the connection cable.
Cuts resulting from running over the connecting cable.
Insulation darnage resulting from forcefully pulling out
of the wall socket.
Cracks through aging of insulation.
Such defective electrical connection cables must not
be used as the insulation darnage makes them ex-
tremely hazardous.
Check electrical connection cables regularly for darnage.
Make sure the cable is disconnected from the mains
when checking.
Electrical connection cables must comply with the regu-
lations applicable in your country .
Single-phase motor
The mains voltage must coincide with the voltage
specied on the motor.s rating plate.
Dimension cables up to a length of 25 m must have
a cross-section of 1.5 mm
2
. and beyond 25 m at least
2.5 mmª.
The connection to the mains must be protected with
a 16 A slowacting fuse.
25 / 132