3. CHANGE HAND (IF NECESSARY):
NOTE: The locks are shipped as ordered from factory. If it is
necessary to change the hand of the lock, follow the steps
below:
TO CHANGE HAND OF LOCK CASE:
A. With bolt fully extended, insert change pin (included in the
hardware pack) into hole. (It will snap over a groove on the
main shaft, holding it in place.)
B. Remove set screw in bolt so bolt can be removed.
C. Rotate bolt and reinstall on to shaft. Do not remove spring.
D. Apply thread locking compound to set screw.
Loctite 242 recommended.
E. Install and tighten set screw (from other side, as shown).
F. Remove change pin.
5/32” SOCKET CAP SCREW
LOCTITE 242 RECOMMENDED
OUTSIDE ESCUTCHEON
ADAPTER
LEVER
OUTSIDE HANDLE
CHANGE PIN
LOCK CASE
BOLT
(AUTOBOLT SHOWN)
TO CHANGE HAND OF LEVERS:
A. Loosen 5/32” socket cap screw and remove lever.
B. Rotate handle to opposite position.
C. Apply thread locker to screw. Loctite 242 recommended.
D. Reinstall handle.
E. Repeat for inside escutcheon (not shown).
NOTE:
Some lever designs
require an adapter.
A
B
C
E
D
F