LED REFERENCE
Most LED indicators are confi gured with the HHD. See Schlage Utility Software (SUS) User Guide for
more information.
Schlage Button
Condition Lights
Access denied 2 red blinks
Access denied, user outside time zone 4 red blinks
Factory default reset One-second solid green with one-second beep
Waiting for PIN Mode 0 only: 5 left red with right green blinks,
then solid right green
Low battery indicator, AA batteries 9 left red blinks
Low battery indicator, coin cell battery 9 right red blinks
Momentary unsecured access 1 green blink, then one red blink on relock
USB active with no physical connection Left green blinking
Optional Inside Push Button (IPB)
Action Lights
Offi ce Mode –Allows lock to toggle between locked (normal) and unlocked state
Press IPB to lock 1 red blink
Press IPB to unlock
1
1 green blink
Privacy Mode – Allows the lock to toggle between normal access and a state in which normal
credentials are ignored
With door closed, press IPB to engage privacy
2
4 green blinks
With door closed, press IPB to release privacy
3
4 red blinks
1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again.
2 On locks confi gured with a mortise-deadbolt, throwing the deadbolt will also engage privacy.
3 If DPS is used, then opening door will also release privacy. If a mortise-deadbolt is used, then retracting the
deadbolt will also release privacy.
TROUBLESHOOTING
For troubleshooting, visit to www.schlage.com/support.
FCC STATEMENTS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received,