User Guide

Introduction | Specifications
Schlage • OEM 200 Developer guide • 11
Electrical Specifications
Symbol Parameter Min Typical Max Units
T Operating Temperature -35 0 65 oC
F Frequency 125kHz and
13.56MHz
Hz
V
in DC Voltage Input 5 16* V
I
AVG Average Current at 12V 50 mA
I
MAX Max Current at 12V 100 mA
W
OL Wiegand Output Logic Low 0 0.4 V
W
OH Wiegand Output Logic High 5 V
TTL
OL TTL Interface Logic Low 0 0.495 V
TTL
OH TTL Interface Logic High 2.65 3.3 3.6 V
O
I General Output Current 25 mA
O
OL General Output Logic Low 0 0.495 V
O
OH General Output Logic High 2.65 3.3 3.6 V
O
PW General Output Pulse Width 150 ms
CAUTION
* Application of more that 16V
may damage the device.
Interface Descriptions
Wiegand Output: Common data interface in an access control system consisting of D0 and D1 Wiegand communication
lines. For more information see this basic reference: https://en.wikipedia.org/wiki/Wiegand_interface
TTL: Serial interface to enable bi-directional communication between the OEM 200 and the host device. For more
information see this basic reference: https://en.wikipedia.org/wiki/Universal_asynchronous_receiver/transmitter. The OEM
200 internally utilizes 1k pull-ups on the TTL interface.
General Output: Digital output that is normally low and goes high indicating that the OEM 200 successfully read a card. The
Host device can use this signal to sound a buzzer or turn on a light.
Read Range
Card Read Range in Free Space*
Card Frequency Card Type Read Range
125kHz ASK, FSK Up to 2.75 inches
13.56MHz ISO 15693 Up to 2.75 inches
13.56MHz ISO 14443A MIFARE Classic Up to 3.25 inches
13.56MHz ISO 14443A MIFARE DESFire EV1 Up to 1.25 inches
13.56MHz ISO 14443A MIFARE Plus Up to 1 inch
* Antenna location inside end product and surrounding materials will affect the read range performance. See Mounting