Antenna Connection
A four-inch flat flexible cable (FFC) is included with the OEM 200 to connect the main board to the antenna board. Verify
that the antenna cable connection at the main board and antenna board are connected correctly. To do this, very gently tug
the ribbon at each connector, being very careful not to dislodge the ribbon from the connector. The best verification step is to
ensure the ribbon is securely fastened into both connectors and verify that card reads are successful.
Step 1: Note that the cable locking
mechanism on the connector is shipped in
the closed position by default.
Closed
Step 2: Gently pull grey cable locking
mechanism away from connector to the
open position as shown.
Open
Step 3: Insert cable into connector with the
blue reinforcement tape facing down.
Step 4: Verify the cable is oriented correctly
before proceeding.
This image shows the ribbon incorrectly
inserted into the cable connector.
Step 5: While maintaining proper ribbon
cable alignment in the connector, firmly push
the grey cable locking mechanism to the
closed position.
Step 6: Following steps 2 – 5 above, connect
the other end of the ribbon cable to the
antenna board.