User Guide

12 • Schlage • OEM 200 Developer guide
Introduction | Specifications
Credential Specifications
Card Technologies Supported
125 kHz Technologies
GE®/CASI® Proximity
HID® Proximity (Except Long Format)
AWID® Proximity
LenelPro
13.56 MHz Technologies
ISO14443 MIFARE DESFire™ EV1 with PACSA enabled
(format in the card – up to 48 bits)
ISO14443 Secure MIFARE® Classic:
XceedID™ MIFARE® app enabled (format in the card
– up to 48 bits)
OESM (dormant – ready to be enabled by end-user)
ISO14443 MIFARE Plus
ISO14443 PIV enabled 75-bit format (other formats
available)
iClass/Inside UID enabled 40-bit format
ISO15693 UID enabled 40-bit format
ISO14443 UID disabled (can be enabled if PIV, EV1, and
MIFARE® are all disabled)
Felica CSN
aptiQmobile
CAUTION
OEM 200 assemblies are susceptible to
damage by Electrostatic Discharge (ESD).
Host Connector Specifications
Connection to the host device can be installed into the OEM 200’s 7-position host connector without tools. The push-in
spring connection can accept wire sizes of 20AWG to 26AWG with the insulator stripped 6 mm. To release a wire from the
connector insert small screw driver with blade with a tip of 2mm into the slot directly above the wire terminal. This will
release the spring clamp and free the wire from the connector.
Refer to Phoenix Contact p/n: 1771075 for more details. https://www.phoenixcontact.com/us/products/1771075
The wire length between the OEM 200 and host device is recommended to be 1 meter or less. However, if an application
requires longer a cable distance consider the effects of voltage drop and signal integrity across a longer distance.
Pin Signal Connector
7 Wiegand D0 Host Connector
J1
6 Wiegand D1
5 Ground
4 General Output
3 TTL – TX
2 TTL – RX
1 Vin*
CAUTION