User Guide
Table Of Contents
12 • Schlage • OEM 200 Developer guide
Introduction | Specifications
Credential Specifications
Card Technologies Supported
125 kHz Technologies
• GE®/CASI® Proximity
• HID® Proximity (Except Long Format)
• AWID® Proximity
• LenelProx®
13.56 MHz Technologies
• ISO14443 MIFARE DESFire™ EV1 with PACSA enabled
(format in the card – up to 48 bits)
• ISO14443 Secure MIFARE® Classic:
• XceedID™ MIFARE® app enabled (format in the card
– up to 48 bits)
• OESM (dormant – ready to be enabled by end-user)
• ISO14443 MIFARE Plus
• ISO14443 PIV enabled 75-bit format (other formats
available)
• iClass/Inside UID enabled 40-bit format
• ISO15693 UID enabled 40-bit format
• ISO14443 UID disabled (can be enabled if PIV, EV1, and
MIFARE® are all disabled)
• Felica CSN
• aptiQmobile
CAUTION
OEM 200 assemblies are susceptible to
damage by Electrostatic Discharge (ESD).
Host Connector Specifications
Connection to the host device can be installed into the OEM 200’s 7-position host connector without tools. The push-in
spring connection can accept wire sizes of 20AWG to 26AWG with the insulator stripped 6 mm. To release a wire from the
connector insert small screw driver with blade with a tip of 2mm into the slot directly above the wire terminal. This will
release the spring clamp and free the wire from the connector.
Refer to Phoenix Contact p/n: 1771075 for more details. https://www.phoenixcontact.com/us/products/1771075
The wire length between the OEM 200 and host device is recommended to be 1 meter or less. However, if an application
requires longer a cable distance consider the effects of voltage drop and signal integrity across a longer distance.
Pin Signal Connector
7 Wiegand D0 Host Connector
J1
6 Wiegand D1
5 Ground
4 General Output
3 TTL – TX
2 TTL – RX
1 Vin*
CAUTION