P516-270 CO-100 OFFLINE LOCK USER GUIDE INSTRUCTIONS FOR CORE SERIES OFFLINE LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
CO-100 Offline Lock User Guide CONTENTS Overview........................................................................................................................................ 3 Getting Started .............................................................................................................................. 4 Construction Access Mode ............................................................................................................ 4 Manual Lock Programming ...................
CO-100 Offline Lock User Guide OVERVIEW The Schlage CO-100 is an off-line electronic lock in the CO-Series product line. • Two factory-configured functions are available: 1) Classroom/Storeroom, and 2) Office. • The lock is powered by four (4) AA batteries. See Batteries on page 9 for more information. • Outside lever is normally locked. • Inside lever always allows egress.
CO-100 Offline Lock User Guide GETTING STARTED Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock, or visit www.schlage.com/support, for more information. 2. Test the lock for proper mechanical and electronic operation. See Testing on page 7 for more information. 3. When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual Lock Programming on page 5-6 for more information. 4.
CO-100 Offline Lock User Guide MANUAL LOCK PROGRAMMING Right LED Left LED Credential Types Credential Type Programming Normal Use Toggle Freeze Pass-Through Function Used to program the lock – does not unlock the lock Unlocks the lock Changes the state of the lock unless in Freeze state Maintains the lock in current state until Freeze PIN is entered again Unlocks a lock momentarily, regardless of state Description Default PIN Five-digit code 97531 and PIN (3 - 6 digits) 13579 and PIN (3 - 6 digit
CO-100 Offline Lock User Guide Manual Programming Commands Commands are confirmed by five alternating green blinks of the Schlage button. The right LED on the Schlage button will blink green to indicate an incorrect entry. To interpret blink patterns, refer to Error Codes on page 7. Function Change [Programming Code] Add Normal Use PIN Wait For Confirmation1 Wait for Press [Programming Code] New [Programming Code] to stop flashing between each step.
CO-100 Offline Lock User Guide USING THE LOCK After PIN credentials have been programmed, enter a PIN to operate the lock as follows: Credential Action Press a valid PIN Green LED will blink and access granted The “#” key is used as ENTER key for PINs with fewer than six digits. If the PIN credential is entered incorrectly, press “ * ” to start over. ERROR CODES All error codes are indicated on the Schlage button by a solid red LED and a blinking green LED.
CO-100 Offline Lock User Guide RESETTING TO FACTORY DEFAULTS ! All information in the lock will be deleted and reset to factory defaults! In the factory default reset state, offline locks have a default PIN of 13579 and “#”, which can be used for installation and testing. Follow these steps to reset to factory defaults. 1. Remove the top inside cover. 2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for power to run out in the lock. 3.
CO-100 Offline Lock User Guide BATTERIES Installing or Replacing Batteries 1. Remove the battery cover. 2. Remove the Battery Bracket. 3. Install the new batteries. Observe polarity. (Install only new AA Alkaline batteries.) 4. Install the Battery Bracket. 5. Connect the batteries. 6. Reinstall the battery cover. ! CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s instructions.
CO-100 Offline Lock User Guide LED REFERENCE Schlage Button Condition Access denied Factory default reset Low battery indicator, AA batteries Momentary unsecured access Lights 2 red blinks One-second solid green with one-second beep 9 left red blinks 1 green blink, then one red blink on relock Optional Inside Push Button (IPB) Action Office Mode Press IPB to lock Press IPB to unlock 1 Lights 1 red blink 1 green blink 1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB
CO-100 Offline Lock User Guide 11
© 2010 Ingersoll-Rand Company P516-270 ENG online Rev.