RESET TO FACTORY DEFAULTS
!
All information in the main controller in the lock will be deleted and reset to factory defaults!
!
Main controller confi gurations that will reset to factory default include: programming and
user codes.
!
The door must be locked (not toggled open or in the middle of normal access) before
resetting to factory defaults.
Follow these steps to reset to factory defaults.
1. Remove the top inside cover.
2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for power to run
out in the lock.
3. Press and hold the Schlage button while reconnecting the battery into the battery pack to resupply
power.
4. Continue holding the Schlage button, and wait for two beeps to sound and two green blinks of the
Schlage button.
5. Release the Schlage button.
6. Press and release the Schlage button three (3) times within 10 seconds of the beeps and blinks at
step 4. One beep will sound and one red blink will occur with each press.
7. The Schlage button will light green for one second and a one-second beep will sound, indicating
that the lock has been reset.
If the Schlage button is not pressed 3 times within 10 seconds, two beeps and two red blinks
indicate timeout.
8. Replace the top inside cover.
To test, enter 13579 and “#”. The Schlage button will blink and the lock will unlock momentarily.