CO-100 Offl ine Lock User Guide
LED REFERENCE
Schlage Button
Condition Lights
Access denied 2 red blinks
Valid PIN entered while lock in Freeze mode 12 red blinks indicating lockout
Factory default reset One-second solid green with one-second beep
Low battery indicator, AA batteries 9 left red blinks
Momentary unsecured access 1 green blink, then one red blink on relock
Optional Inside Push Button (IPB)
Action Lights
Offi ce Mode
Press IPB to lock 1 red blink
Press IPB to unlock
1
1 green blink
1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again.
TROUBLESHOOTING
Problem Possible Cause Solution
The lock does not
function when a
valid PIN credential
is entered, or the
lock beeper does
not sound.
The beeper may be
turned off.
The battery or
wired power may be
improperly connected.
The batteries may be
inserted with incorrect
polarity.
The batteries may be
depleted.
If applicable, the IPB
through-door ribbon
cable may not be
properly plugged in, or
may have bent pins.
Use manual programming to enable the beeper (see
Disable/Enable Beeper on page 7).
Check that the battery or wired power is connected
correctly.
Check that batteries are inserted in the correct polarity.
Replace batteries.
Check that the optional IPB through-door ribbon
cable is plugged in correctly (if applicable). The red
wire should be on the left and not pinched in the door.
Check that there are no bent pins on the optional
IPB through-door cable.
Refer to the installation instructions that came with
the CO-100 lock, or this user guide for details on the
above mentioned procedures.