User Guide

11
CO-200 Offl ine Lock User Guide
RESET TO FACTORY DEFAULTS
!
All information in the lock will be deleted and reset to factory defaults!
!
The door must be locked (not toggled open or in the middle of normal access) before
resetting to factory defaults.
Level 1 Factory Default Reset
Level 1 factory default reset will delete confi gurations and settings in the main controller in the lock.
Main controller confi gurations that will reset to factory default include: programming and user
codes.
Level 1 factory default reset will not reset confi gurations and settings in the reader.
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the
Schlage button, indicating confi rmation.
2. After confi rmation signals, release the Schlage button.
3. Rotate the mechanical key within 10 seconds and hold. Continue holding the key until
confi rmation signals are observed.
4. The Schlage button will light green for one second and a one-second beep will sound to confi rm
reset to factory defaults.
If the mechanical key is not rotated within 10 seconds, two beeps and two red blinks indicate
timeout.
Level 2 Factory Default Reset
Level 2 factory default reset will delete all confi gurations and settings in the lock and the reader.
Reader confi gurations that will reset to factory default include: keypad format, magstripe reader
track, beeper on/off, and contactless card.
Days in Use counter and lock type confi gurations will not reset.
To complete Level 2 factory default reset, repeat steps 2 through 5 within 10 seconds of the
confi rmation signals of Level 1 factory default reset.
If more than 10 seconds pass after the confi rmation signals of Level 1 reset, then Level 1 reset will be
repeated.
Factory Default Reset Following Reader Replacement
Should the lock's reader require replacement, an identical type reader must be used
(i.e., magswipe type replaced with magswipe).
After replacement with an identical type reader, perform both Level 1 and 2 Factory Default
Reset.