CENTRON Meter Technical Reference Guide 4-3
Resetting Values
The pointers on the clock module are spring fitted to their staffs and can be easily
repositioned to reset the register (see Figure 4.3).
Figure 4.3 Clock Register
To reset the cyclometer register dials:
1 First move the spring-loaded wire off of the hook that holds it in place.
When the hook is in place, it puts tension on the individual cyclometer dials.
After moving the wire off of its hook, a washer that helps to hold the dials in
place will be free to move on the dial axle.
2 At that point, move all of the dials to the left (as viewed from the front of the
cyclometer). From right to left, one by one, move each dial to zero.
3 After each dial is set to zero, press it to the right and hold all zeroed dials in
place. They will interlock with each other and will not move.
4 After resetting each dial to zero, keep the dials locked together, move them to
the right side, and reset the spring-loaded wire to its hooked resting place.
5 Be sure to secure the washer against the left-most dial with the hinge by
replacing the spring-loaded wire on the left side of the washer.
At that point, the spring-loaded wire will place tension against the washer and dials
and the cyclometer will be ready to operate again.