User's Manual

Operation: C1SD, C1ST, and C1SL Versions
5-12 CENTRON Meter Technical Reference Guide
Test Mode Data
The following items shown in Table 5.5 can be displayed in Test mode.
Table 5.5 Test Mode Data Items
Item Description
Time Remaining in the (Sub) interval
The amount of time in minutes and seconds before the end
of the current Test mode demand interval.
Maximum kW
The maximum demand since the meter was put into Test
mode. This value will be set to zero each time a demand
reset is performed.
Previous kW
The kW demand of the previous Test mode subinterval/
interval.
Input Pulse Count
The number of pulses that have been received since the
last reset in Test mode.
Note: The display will be updated with each input pulse.
Previous Interval # of Input Pulses
The number of pulses received during the last complete
interval or subinterval in Test mode.
KWh The energy accumulated in Test mode.
Present (Accumulating) kW
The calculated demand value as it increases from the start
of a demand test interval to the end of the subinterval/
interval.
Time Remaining until Test Mode
Timeout
The amount of time in minutes and seconds before the
programmed Test mode timeout counter will expire.