User's Manual

MPI: GE, 240v, Single Phase, Remanufacturing Process
97-xxxx, Rev:A Page 5 of 13
5 AC Cable Disconnection
5.1 Disconnect AC cable from the module. Use needle nose pliers to disconnect power
leads from module. Gently grip on red AC cable tabs with needle nose pliers and
disconnect the power leads. Pay close attention not to touch PCB with pliers and not to
bend connection tabs on the board. Do not rotate tabs when disconnecting power leads.
(Refer to Figure 2)
5.2 Disconnect AC cables from Current Coil. Use needlenose pliers to disconnect power
leads from current coil. Grip on the edge of the superclip and gently remove clip from
current coils. Remove any debris resulting from disassembly of the superclip from the
copper coil.
5.3 Disregard and discard old cables.
5.4 All disassembled modules must be placed in ESD bags for storage.
Note: Old modules (RTOMM) have a different set of cables from the new generation of modules
(BAMM/BAMMCCSK). Both types of cables are NOT exchangeable. The RTOMM cables have
different inline components on each of the two cables. One of two RTOMM cables has a fuse
incorporated on the cable and the other cable has a resistor incorporated on it. The
BAMM/BAMMCCSK have 2 identical cables WITHOUT in line components.
RTOMM
Component Side
Resistor cable
connector
Fuse cable
connector
Figure 2: Power Cable
Orientation