Use and Care Guide

5
Schluter
®
-DITRA-HEAT
Product
Test Method
Performance
Schluter
®
-DITRA-HEAT
ASTM E96*
0.21 perms
Schluter
®
-DITRA-HEAT-DUO 0.48 perms
*Using the water method at 73ºF (23ºC) and 50% RH
6.4 Schluter
®
-DITRA-HEAT Uncoupling and waterproofing membrane
Item No.
Item Dimensions
DH5 12M Roll 3' 3" x 41' 1" = 134.5 ft
2
(1 m x 12.5 m = 12.5 m
2
)
DH5 MA Sheet 3' 3" x 2' 7" = 8.6 ft
2
(1 m x 0.8 m = 0.8 m
2
)
6.4 Schluter
®
-DITRA-HEAT-DUO Uncoupling and waterproofing membrane with thermal break
Item No.
Item Dimensions
DHD810M
Roll
3' 3" x 33' = 108 ft
2
(1 m x 10 m = 10 m
2
)
DHD8MA
Sheet
3' 3" x 2' 7" = 8.6 ft
2
(1 m x 0.8 m = 0.8 m
2
)
Product Item Numbers
U.S. Pat. No. 8,950,141, and U.S. DES. PAT. No. D706459
Canada D Schluter Systems L.P. and other patents pending.
Patent pending
IIC
Impact Insulation Class (IIC) is a rating that characterizes the levels of impact noise transmitted through different floor-ceiling assemblies. It can be
used by architects, builders, and specification and code authorities for acoustical design purposes in building constructions. The rating increases as
the impact sound attenuation of the floor-ceiling assembly increases.
IIC is determined according to ASTM E492 and ASTM E989. The ASTM E492 test method is a laboratory measurement of impact sound transmission
through floor-ceiling assemblies using a standardized tapping machine. The results from this test are then used to calculate a single-number rating per
ASTM E989 that is called impact insulation class.
Delta IIC
Delta Impact Insulation Class (ΔIIC) is a rating that characterizes the reduction in impact noise transmitted through a concrete floor by the addition of
a floor-covering assembly. It can be used to compare the effectiveness of different floor-coverings over concrete and help select different products
and/or systems for acoustical design purposes in building constructions.
ΔIIC is determined according to ASTM E2179. A floor-covering assembly is installed over a standard concrete slab and the IIC of the entire assembly
is determined per ASTM E492 and ASTM E989 as explained above. The ΔIIC rating is obtained by subtracting 28 (the IIC of the concrete slab) from
the IIC of the entire assembly.
Vapor Management
The free space under the DITRA-HEAT and DITRA-HEAT-DUO mattings allow the substrate to breathe, while the material composition provides for a
very low water vapor permeance, which prevents any significant vapor intrusion in the tile assembly from below.
DITRA-HEAT and DITRA-HEAT-DUO effectively manage vapor and prevent damage to the tile covering as a result.
Heating Cables
The DITRA-HEAT-E-HK heating cables sets are certified or listed to the following standards and usage:
CAN/CSA-C22.2 No. 130-03 "Requirements for Electrical Resistance Heating Cables and Heating Device Sets" under usage markings GXW
for general use (G) with a wet rating (W), but specifically (X) for floor embedded indoor floor warming applications.
For products bearing the cCSAus certification mark:
UL 1673 "Electric Space Heating Cables" for installation in poured masonry floors within enclosed structures.
For products bearing the cULus certification mark:
UL 1683 "Outline of investigation for Electric Heating Products For Installation Under Floor Coverings"
Thermostat
DITRA-HEAT-E-WiFi thermostat WiFi radio chip authorized by the FCC (USA) and IC (Canada) under the following numbers:
FCC ID.................AZY-HF-LPT200
IC ID....................12243A-HFLPT2001
The DITRA-HEAT-E-WiFi/-RT/-R digital thermostats are UL listed according to the following standards:
UL 60730-1 “Automatic Electrical Controls for Household and Similar Use – Part 1: General Requirements”
UL 60730-2-9 “Automatic Electrical Controls for Household and Similar Use – Part 2-9: Particular Requirements for Temperature Sensing
Controls”
CSA E60730-1:13 “Automatic Electrical Controls for Household and Similar Use – Part 1: General Requirements”
CSA E60730-2-9 “Automatic Electrical Controls for Household and Similar Use – Part 2-9: Particular Requirements for Temperature Sensing
Controls”
UL 943 4th ed. “Ground-Fault Circuit Interrupters”
CSA C22.2 No. 144.1-06 “Ground-Fault Circuit Interrupters”
Power Module
The DITRA-HEAT-E-RR power module is certified or listed to the following standards:
Listed to UL 60730-1/ UL 60730-2-9 (Thermostat); 943 4th edition (GFCI)
Certified to CSA E60730-1/ CSA E60730-2-9 (Thermostat); C22.2 No. 144.4-06 (GFCI)