Use and Care Guide

3
FLOOR DRAINS
Metallic-coated grates are stainless steel 304
with a metallic coating created using physical
vapor deposition (PVD). The resulting metallic
film is very hard and corrosion-resistant.
Textured color-coated grates are stainless
steel with a powder coat.
Anodized aluminum grates feature
an anodized layer that retains a uniform
appearance during normal use. The surface
may be damaged by grout or setting material.
Therefore, these materials must be removed
immediately.
Installation
The installation instructions below represent the
use of KERDI-DRAIN and KERDI-LINE in floor
applications. Installation instructions for the use
of KERDI-DRAIN and KERDI-LINE in shower
applications can be found in the Schluter
®
-
Shower System Installation Handbook.
KERDI-DRAIN
Preparation
After locating the correct position, cut a hole in
the substrate for the drain outlet and coupling
to the waste line using the template provided.
Note: Fill in box-outs in concrete floors with
dry-pack mortar. A pipe coupling or similar
can be used as a form around the waste
line. Select form to accommodate the drain
outlet and mechanical no-hub coupling (when
applicable). Limit the diameter of the hole to 5"
(125 mm) maximum to ensure proper support
of the tile assembly. A larger hole can lead to
lack of support and damage the tile assembly
(e.g., cracked grout around drain).
Drain installation
Access to plumbing from below
If there is access to the plumbing from below
and the waste line can be connected after
installing KERDI-DRAIN, the drain can be
installed in conjunction with the mortar bed.
1. Place a ring of loose mortar up to the inlet
hole in the floor and firmly press the drain
into the mortar. The bonding flange must
be fully supported to prevent damage to the
tile assembly (e.g., cracked grout around
drain). When installing KERDI-DRAIN over
wood substrates, the minimum thickness
of mortar required at the perimeter of the
bonding flange is 1" (25 mm).
2. The screed is then placed flush with the top
of the bonding flange of the KERDI-DRAIN.
Slope the mortar bed using the bonding
flange and mortar screeds as guides.
No access to plumbing from below
When there is no access to the plumbing
from below, install the KERDI-DRAIN to the
appropriate height prior to the installation of the
shower base.
1. Begin the drain installation by dry fitting
the components. Measure and cut a
section of pipe to connect the KERDI-
DRAIN to the odor trap below the floor,
using the foam spacers included with
the drain as a spacer. When installing
KERDI-DRAIN over wood substrates, the
minimum thickness of mortar required at
the perimeter of the bonding flange is
1" (25 mm).
2. Prepare the odor trap, cut section of
pipe, and KERDI-DRAIN with cleaner,
primer and ABS or PVC cement per the
solvent cement manufacturer's instructions
and connect. Use a no-hub coupling for
stainless steel drains with no-hub outlets,
and thread sealing compound or tape for
stainless steel drains with threaded outlets.
3. Pack loose mortar under the drain up to
the inlet hole to ensure solid and uniform
support of the bonding flange. The screed
is then placed flush with the top of the
bonding flange of the KERDI-DRAIN. Slope
the mortar bed using the bonding flange
and mortar screeds as guides.
Clamping ring drain already installed
If a clamping ring drain is already installed, the
drain must be replaced with KERDI-DRAIN or
converted using the KERDI-DRAIN adaptor kit.
1. If using the KERDI-DRAIN adaptor kit,
remove the clamping ring from the installed
drain and save the bolts for installation
of the adaptor ring. Align the bolt pattern
of the clamping ring with the matching
punch-outs in the adaptor ring. Punch the
matching inserts out through the stainless
steel adaptor ring.
2. Apply a continuous 1/4" - 3/8" (6 - 10 mm)
bead of KERDI-FIX to the underside of the
adaptor ring. Align the holes in the adaptor
ring with the bolt holes in the installed drain
and place the adaptor ring on the installed
drain flange. Re-insert and tighten the bolts
using a star pattern. Bolts are to be finger-
tight plus 1/4 turn; do not overtighten, as
this may warp the adaptor ring and result
in leaks.
3. Slide the adaptor flange into the adaptor
ring and ensure full support under the
adaptor flange with mortar. The screed
is then placed flush with the top of the
bonding flange of the KERDI-DRAIN. Slope
the mortar bed using the bonding flange
and mortar screeds as guides.
Note: Schluter
®
-Systems strongly
recommends a leak test be performed
on the connection between the drain and
waste line prior to continuing on with
the remainder of the installation whenever
possible. Refer to local plumbing and/or
building codes for any specific requirements
in your area.
Connection to waterproofing
membranes
The KERDI or DITRA waterproofing membranes
can be installed over the mortar bed as soon
as it can be walked upon.
KERDI
1. Apply Schluter SET
®
, Schluter ALL-SET
®
,
Schluter FAST-SET
®
or unmodified thin-
set mortar to the bonding flange and
surrounding mortar bed with a 1/4" x 3/16"
(6 x 5 mm) V-notched trowel or the
KERDI-TROWEL, which features a
1/8" x 1/8" (3 x 3 mm) square-notched
design. The thin-set mortar must be mixed
to a fairly fluid consistency, but still able to
hold a notch.
Note: When using the stainless steel
bonding flange, the membrane is bonded
to the integrated bonding flange with
KERDI-FIX adhesive/sealant. The stainless
steel bonding flange must be clean and
free of grease or other contaminants prior
to KERDI-FIX application.
2. Embed KERDI in the bond coat and work
the membrane onto the KERDI-DRAIN
bonding flange and mortar bed with the flat
side of the trowel to ensure full coverage
and remove air pockets. The membrane
is carried to the step in the bonding flange
(template provided).
DITRA or DITRA-XL
1. DITRA or DITRA-XL is installed up to
the outer edge of the KERDI-DRAIN
bonding flange. Apply Schluter SET
®
,
Schluter ALL-SET
®
, Schluter FAST-
SET
®
or unmodified thin-set mortar to
the mortar bed surrounding KERDI-
DRAIN with a 1/4" x 3/16" (6 x 5 mm)
V-notched trowel or the DITRA-TROWEL,
which features an 11/64" x 11/64" (4.5 x
4.5 mm) square-notched design. The thin-
set mortar must be mixed to a fairly fluid
consistency, but still able to hold a notch.
Solidly embed the matting into the bond
coat using a float, screed trowel, or DITRA-
ROLLER.
2. DITRA or DITRA-XL is sealed to the
KERDI-DRAIN bonding flange using
a cut section of the KERDI membrane.
Apply Schluter SET
®
, Schluter ALL-SET
®
,
Schluter FAST-SET
®
or unmodified thin-
set mortar to the bonding flange and
surrounding membrane with a 1/4" x 3/16"
(6 x 5 mm) V-notched trowel or the KERDI-
TROWEL, which features a 1/8" x 1/8"
(3 x 3 mm) square-notched design.
Note: When using the stainless steel
bonding flange, the KERDI is bonded to
the integrated bonding flange with KERDI-
FIX adhesive/sealant. The stainless steel
bonding flange must be clean and free
of grease or other contaminants prior to
KERDI-FIX application.