Installation Guide
Any leveling of the floor must be done 
prior to the installation of the shower tray. 
If necessary, cut the tray to size prior to 
application. The shower base can also be 
extended beyond the tray using dry-pack 
mortar, which is in turn covered with the 
KERDI membrane.
1
Cut the flat end of the KERDI-SHOWER-LT/-LTS tray to fit around the channel support. Apply 
Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, or unmodified thin-set mortar to the substrate using a 1/4" 
x 3/8" (6 mm x 10 mm) square- or U-notched trowel. Slide the KERDI-SHOWER-LT/-LTS under 
the edge of the channel body flush with the surface of the channel support, making certain to 
solidly embed the tray in the mortar. Check the underside of the tray to ensure that full coverage 
is achieved. Note: The thin-set mortar used in this step is to bed and support the tray only.
2
Place a mortar screed opposite the installed 
KERDI-LINE channel body.
1
Fill the remainder of the shower base with 
mortar and slope the mortar bed at 1/4"  
(6 mm) per 12" (305 mm) using the bonding 
flange and a perimeter screed as guides.
2
Schluter
®
-KERDI-LINE with Schluter
®
-SHOWER-LT/-LTS prefabricated tray
Schluter
®
-KERDI-LINE with mortar base
Note: When KERDI-LINE is placed at an intermediate location (e.g., center of a shower), it is recommended that the KERDI-SHOWER-LT trays be cut 
by equal amounts from the ends to ensure a consistent height of the first course of tile. When KERDI-LINE is placed adjacent to the wall, cut the KERDI-
SHOWER-LTS trays from the thicker end to ensure a flush transition at the drain.
As soon as the mortar bed can be  
walked upon, waterproofing with the  
KERDI membrane can begin.
3
1
Apply Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, 
or unmodified thin-set mortar to the floor 
and walls using a 1/4" x 3/8" (6 mm x 10 
mm) square- or U-notched trowel.
2 3
Press the bench firmly into place and check 
the underside and backsides to ensure that 
full coverage and support are achieved. 
Verify that the slope on the surface of the 
bench is directed toward the shower base.
Schluter
®
-KERDI-BOARD-SB bench
Install KERDI-BAND and KERDI-KERECK 
and KERDI-KERS-B (for triangular bench) 
to cover all seams and corners, ensuring a 
minimum 2" (50 mm) overlap, and work the 
membrane into the mortar to achieve full 
coverage and remove air pockets.
INSTALLATION — Shower base with Schluter
®
-KERDI-LINE 31