Installation Guide
INSTALLATION — Shower base with Schluter
®
-KERDI-DRAIN-H 27
Dry fit the Schluter
®
-KERDI-SHOWER-CB 
compensation board and KERDI-SHOWER tray. If 
necessary, cut the tray and compensation board to 
size. Take measurements for the drain flange and 
ABS/PVC outlet pipe locations. 
Place the KERDI-SHOWER-CB compensation 
board and solidly embed in the mortar. 
Apply Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, or 
unmodified thin-set mortar to the top of the KERDI-
SHOWER-CB compensation board using a 1/4" x 
3/8" (6 mm x 10 mm) square- or U-notched trowel. 
Place the KERDI-SHOWER tray and solidly embed 
in the mortar. 
1
4
7
Mark and cut compensation board for the KERDI-
DRAIN-H flange opening using the template 
provided (maximum 5" (125 mm) diameter). Mark 
and cut a 2-3/4" (70 mm) – 3" (76 mm) maximum 
wide slot for the ABS/PVC outlet pipe. Do not 
exceed the maximum to ensure proper tile support.
2
Dry fit the plumbing components. Measure and 
cut a section of pipe to connect KERDI-DRAIN-H 
to the odor trap using the detachable center 
section of the tray, or foam spacers included with 
the drain, as a spacer. Proper slope MUST be 
maintained to ensure adequate drainage. Prepare 
the pipe and KERDI-DRAIN-H with cleaner, 
primer, and ABS or PVC cement per the solvent 
cement manufacturer’s installation instructions and 
connect. 
Note: Schluter Systems strongly recommends a 
leak test be performed on the connection between 
the drain and the waste line prior to continuing with 
the remainder of the installation whenever possible. 
Refer to local plumbing/or building codes for any 
specific requirements in your area.
5
Apply Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, or 
unmodified thin-set mortar to the bonding flange 
and recess area in the tray with a 1/4" x 3/16" 
(6 mm x 5 mm) V-notched trowel or the KERDI-
TROWEL. The thin-set mortar must be mixed to a 
fairly fluid consistency, but still able to hold a notch. 
Embed the KERDI membrane collar in the bond 
coat and work the membrane onto the KERDI-
DRAIN bonding flange and shower base to ensure 
full coverage and remove air pockets.
8
Apply Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, or 
unmodified thin-set mortar to the substrate using a 
1/4" x 3/8" (6 mm x 10 mm) square- or U-notched 
trowel.
3
Apply Schluter SET
®
, ALL-SET
®
, FAST-SET
®
, 
or unmodified thin-set mortar to the KERDI-
SHOWER-CB compensation board and to the top 
and bottom of the detached center section of the 
KERDI-SHOWER tray. Slide the center section into 
place below the drain to ensure solid and uniform 
support of the bonding flange.
Note:   If mosaic tiles (tile format less than 2" x 
2" (50 mm x 50 mm)) will be used on the shower 
tray, the shower tray seam is located over the pipe 
cut-out, or the tray will be exposed to heavy loads 
the slot in the compensation board must be filled 
with a sand mortar or dry-pack to ensure proper 
support of the tile assembly.
6
Seal inside corners by abutting adjacent sheets 
and installing KERDI-BAND with Schluter SET
®
, 
ALL-SET
®
, FAST-SET
®
, or unmodified thin-set 
mortar, centered over the joint. Install KERDI-
KERECK prefabricated waterproofing corners at 
all inside and outside corners. When using the 
KERDI-BOARD-SC curb, seal the curb to the 
base and walls using KERDI-KERECK and KERDI-
BAND. 
9
Preparation
Plywood, OSB or concrete subfloor must be clean, even, and load bearing. Any leveling must be done prior to compensation board and shower tray 
installation. 
Schluter
®
-KERDI-DRAIN-H
Please refer to Schluter
®
-Systems' installation videos in addition to reading the instructions below.
INSTALLATION