Instructions / Assembly

2 3 4 5 6 7 8 9
Installation Manual
Schluter
®
-DITRA-HEAT-E-RS1
Smart Thermostat
WARNINGS
The installation of this thermostat must be performed by qualified personnel
and comply with the national and local electrical codes and regulations.
To avoid electric shock, disconnect the heating system power supply at the
main electrical panel before installation and maintenance of the thermostat.
THERMOSTAT INSTALLATION APPLICATION SETTINGS
1. Loosen the screw
at the bottom and
remove the faceplate.
2. Connect the heating cable to the load terminals
and the power supply wires to the line terminals
located on the back of the thermostat. Connect
the heating cable ground wire to the grounding
screw in the electrical junction box.
3. Connect the temperature sensor as shown. Use
the floor temperature sensor supplied with the
DITRA-HEAT-E-HK heating cable(s). Any other
type of sensor used needs to be 300 volt rated
and meet the other requirements of the electrical
codes in your region.
5. Replace the cover and tighten the screw at the
bottom.
4. Use the screws
provided to secure
the thermostat
to the electrical
junction box.
6. Power up the thermostat. After performing a test
sequence, the thermostat should display the floor
temperature. If not, refer to the troubleshooting
guide in this manual.
(Can also be done with the app)
1. Press the dot soft button and hold for 1 second to
access the menu. Press the appropriate arrow to
move up and down into the choices and press the
dot soft button to make a selection and move to
the next parameter, until reaching the end.
2. Settings Which Can Be Modified with the Device
Setting No. Name
Parameter and
possible settings
Further Explanation
1 Temperature
Temperature unit:
°F or °C
(default: °F)
2 Control
Control Mode:
Floor or Ambient
(default: Floor)
The thermostat offers 2 temperature regulation modes:
Floor mode: Regulates floor temperature by means of an external floor
temp. sensor.
Ambient mode: Regulates ambient temperature by means of an internal
temp. sensor.
3
Max Floor
Temperature
Max. floor temperature limit
when in Floor control mode or
in Ambient mode:
41°F to 97°F
(OFF option, available only in
ambient control mode)*
This function limits the floor temperature when in floor control mode
or in ambient control mode. This is ideal for preventing uncomfortable
temperatures, or for preserving floor coverings other than ceramic or stone
tiles. The recommended max. set point temperature for alternative floor
coverings (e.g. LVT flooring, laminate flooring, etc.) is 82°F or 28°C. When
reaching 82°F (28°C), “Laminate flooring” will be displayed.
4 Aux Output
Auxiliary output:
OFF, EXP, Fast, Long
(default: OFF)
An auxiliary output provides one of three functions for an additional heating
source:
EXP: For connecting one or more Schluter
®
-DITRA-HEAT-E-RRS power
modules
Fast and Long: For adding second stage heating when in ambient control
mode (Please consult our White Paper on this subject in the “Download”
section of this thermostat on our website.)
5 Floor Sensor
Floor temperature sensor:
10K or 12K
(default: 10K)
MANUAL TEMPERATURE
ADJUSTMENTS
To adjust the temperature, press the up or
down arrow to change the set point temperature.
This installation manual is subject to change without notice.
Please visit www.schluter.com for the latest version.
CONNECT THE THERMOSTAT
TO THE SCHLUTER
®
SMART
THERMOSTAT APP
1. If you do not yet have an account, download
the Schluter
®
Smart Thermostat app for iOS or
Android™ to create an account and add your
device.
2. Tap the menu icon on your smart phone, then
select “Add Device”
3. Follow the steps of the Installation Wizard.
* In floor control mode, the set point
limit is 97°F (36°C).

Summary of content (2 pages)