Shower Installation Guide
INSTALLATION — Shower Assembly with Mortar Base 15
Use KERDI-KERECK-F pre-formed inside and
outside corners to seal the shower curb to the
wall and mortar base. The curb/base junction
is sealed using KERDI-BAND. Cover the curb
with KERDI.
8
Protect walls and ceiling* from moisture and
vapor penetration using KERDI. Seams are
constructed by overlapping the edges of KERDI
by 2" (50 mm) minimum or by butting adjacent
sheets of KERDI and installing KERDI-BAND,
centered over the joint.
*Applies when installing KERDI on the ceiling. KERDI
application on ceiling is required for steam showers and
optional for showers and tub surrounds.
9
Install KERDI-SEAL-PS pipe seals at shower-
head, body sprays, etc. and KERDI-SEAL-MV
mixing valve seal at the mixing valve. As an
alternative, KERDI-FIX or equivalent sealant can
be used to seal pipe protrusions and protect
moisture-sensitive solid backing panels at the
mixing valve.
10
The KERDI waterproofing application is now
complete. Prior to setting tile, wait 24 hours
minimum before water testing to allow for final
set of thin-set mortar and ensure waterproof
performance at seams and connections.
Before and during tile installation, the KERDI on
the mortar base must be protected in a suitable
manner (e.g., cardboard can be laid over the
floor to protect against mechanical damage).
Using a trowel that is appropriate for the size
of the tile, apply unmodified thin-set mortar
directly to the exposed KERDI surface and
install the tiles, ensuring full coverage.
11
The grate assembly is installed in conjunction
with the tile. Place the height adjustment collar
inside the lateral adjustment ring and snap the
grate into place. Fill the step in the bonding
flange with thin-set mortar and back-butter the
underside of the grate to ensure full support.
Press the assembly into the mortar and install
the surrounding tiles. Position the grate to
match the joint pattern of the tile covering and
press flush with the tile surface.
Note: Protect the visible surface of the
grate from contact with setting and grouting
materials. In particular, anodized aluminum is
sensitive to alkaline materials.
12
KERDI, KERDI-BAND, KERDI-KERECK-F, KERDI-SEAL-PS, and KERDI-SEAL-MV are installed using unmodified thin-set mortar (mixed to a fairly fluid consistency, but still able to
hold a notch). Dampen particularly dry and porous substrates in order to help prevent premature drying or skinning of the thin-set mortar. Apply the thin-set mortar using a 1/4" x
3/16" (6 mm x 5 mm) V-notched trowel or the Schluter
®
-KERDI-TROWEL, which features a 1/8" x 1/8" (3 mm x 3 mm) square-notched design. Embed the membrane into the mortar
throughout its entire surface to ensure proper adhesion and to remove air pockets. Periodically lift up a corner to check the fleece for full coverage. The sequence of membrane
installation can vary provided that a minimum 2" (50 mm) overlap is maintained at all joints and proper connection to the KERDI-DRAIN is established. Note: Top-over-bottom or
shingle laps of the membrane are not required.
KERDI-SEAL-PS/-MV KERDI-FIX