Use and Care Manual

SHOWER ASSEMBLY — Schluter
®
-KERDI-BOARD waterproof building panel 9
Areas of Application
Interior showers.
Over wood or concrete subfloors. See the Base information under
Requirements (below) for details.
Areas requiring disabled access/curbless applications; see detail K-SHBF
on page 12.
Limitations
Certain glass tiles may not be compatible with bonded waterproof
membranes and/or may require special setting materials. Consult glass
tile manufacturer and Schluter
®
-Systems for more information.
Certain moisture-sensitive stones, e.g., green marble, or resin-backed
tiles, may not be appropriate for use in wet areas such as showers or
may require special setting materials. Consult stone supplier and
Schluter
®
-Systems for more information.
Do not use sawn lumber curbs on concrete subfloors subject to
moisture migration.
Requirements
Plywood, OSB, or concrete subfloor must be clean, even, and load bearing.
Base – KERDI-SHOWER-T/-TS/-TT/-LT/-LTS or Portland cement mortar
bed.
Curb – KERDI-BOARD-SC, KERDI-SHOWER-SC, KERDI-BOARD,
concrete, masonry block, or sawn lumber sheathed with solid backing
(see below).
Bench – KERDI-BOARD-SB, KERDI-SHOWER-SB, KERDI-BOARD,
concrete, masonry block, or sawn lumber sheathed with solid backing
(see below).
Solid backing – gypsum wallboard, cementitious backer unit, fiber-
cement underlayment, fiber-reinforced water-resistant gypsum
backerboard/underlayment, coated glass mat water-resistant gypsum
backerboard, Portland cement mortar bed, concrete, or masonry.
KERDI-DRAIN/-LINE shall be properly supported.
KERDI-DRAIN/-LINE shall be connected to the waste line; use ABS
cement for ABS drains, PVC cement for PVC drains, a no-hub coupling
for stainless steel drains with no-hub outlets, and thread sealing
compound or tape for stainless steel drains with threaded outlets.
Minimum KERDI-BOARD thickness – 1/2" (12.5 mm) for studs spaced at
16" (40.6 cm) o.c. and 3/4" (19 mm) for studs spaced at 24" (61.0 cm) o.c.
KERDI-BOARD shall be fastened to wood or metal framing with appropriate
screws (i.e., coarse thread wood screw for wood studs and self-tapping for
metal studs) and corresponding KERDI-BOARD-ZT washers. Screws must
reach a depth of at least 3/4" (20 mm) in wood studs and 3/8" (10 mm) in
metal studs. Maximum allowable on-center fastener spacing is 12" (30 cm)
for walls and 6" (15 cm) for ceilings.
KERDI-BOARD shall be installed up to the height of the showerhead
at minimum.
In enclosed shower areas, install KERDI waterproofing membrane on all
surfaces, including the ceiling, door jambs and the door header.
Any protrusions through the KERDI-BOARD (e.g., showerhead, mixing
valve, etc.) must be treated with KERDI-SEAL-PS/-MV seals, KERDI-FIX
or suitable sealant.
When using the stainless steel KERDI-DRAIN bonding flange, use
KERDI-FIX to bond KERDI to the drain.
All horizontal surfaces (e.g., benches, curbs, window sills, shelves, etc.)
must be sloped toward the shower drain. This can be done by sloping
the substrate or the tile.
Substrate Preparation
Verify that subfloor panels are properly fastened to framing members.
Any leveling of the subfloor must be done prior to installing
KERDI-SHOWER-T/-TS/-TT/-LT/-LTS/-SB/-SC/-SR or KERDI-BOARD-
SC/-SB.
Solid Backing Materials
Gypsum wallboard – ASTM C1396/C1396M
Cementitious backer unit – ANSI A118.9 or ASTM C1325
Fiber-cement underlayment – ASTM C1288
Fiber-reinforced water-resistant gypsum backerboard/underlayment –
ASTM C1278
Coated glass mat water-resistant gypsum backerboard – ASTM C1178
Portland cement mortar – ANSI A108.1B
Concrete
Masonry
Setting and Grouting Materials
Unmodified thin-set mortar – ANSI A118.1
Grout – ANSI A118.3, A118.6, A118.7
Installation Specifications
Portland cement mortar bed – ANSI A108.1B
Tile – ANSI A108.5
Grout – ANSI A108.6, A108.10
Other Considerations
When KERDI-SHOWER-T/-TS/-TT/-LT/-LTS tray dimensions do not
match the dimensions of the shower compartment, the tray may be cut
or extended with dry pack mortar.
Shower grab bars must be anchored in the structure or solid blocking
behind KERDI-BOARD.
When KERDI-BOARD and tile are installed on the ceiling, the fasteners must
be able to support the load of the tile and setting and grouting materials.
A water test is strongly recommended before setting tile to verify a
successful installation. Wait 24 hours minimum after the membrane
installation is complete to allow for final set of thin-set mortar and ensure
waterproof performance at seams and connections. Refer to local
plumbing codes for any specific requirements in your area.
Schluter
®
-Systems profiles may be used to finish and protect outside
corners and eliminate the use of sealant at inside corners; see page 37.
Schluter
®
-SHOWERPROFILE-S/-R profiles eliminate the need for cutting
wedges of tile by covering the exposed wall area where the floor slopes
to KERDI-LINE.
Showers Ceramic or stone tile
K-SH-KB-19
Schluter
®
-KERDI-BOARD waterproof building panel