Installation Guide

32 INSTALLATION — Bathtub surround — Schluter
®
-KERDI-BOARD
KERDI-BOARD can be mounted
vertically or horizontally on framing with
appropriate screws and corresponding
KERDI-BOARD-ZT washers. Minimum board
thickness = 1/2" (12.5 mm) for studs spaced
at 16" (40.6 cm) o.c.; 3/4" (19 mm) for studs
spaced at 24" (61.0 cm) o.c. Screws must
reach a depth of at least 3/4" (20 mm) in wood
studs and at least 3/8" (10 mm) in metal studs.
1
Abut panels over the center of the studs
or other solid backing. Screws may be
placed between adjacent panels such that
the washers fasten both panel edges. The
maximum allowable on-center fastener
spacing is 12" (30 cm) for walls and
6" (150 mm) for ceilings.
2
Place painter’s tape to protect the tub deck.
Apply unmodified thin-set mortar to the
KERDI-BOARD using a 1/4" x 3/16"
(6 mm x 5 mm) V-notched trowel or
the KERDI-TROWEL. Completely fill the
1/4" (6 mm)-wide gap between the
KERDI-BOARD and tub with KERDI-FIX or
other suitable sealant.
Note: When KERDI-BOARD is installed
above the tub flange, apply KERDI-FIX to
the tub flange and spread using a small
notched trowel.
3
Schluter
®
-KERDI-BOARD over wood or metal framing
Apply KERDI-BAND waterproofing strips.
Solidly embed the membrane in the mortar
and KERDI-FIX to ensure full coverage and
remove air pockets.
4
KERDI-BOARD joints, corners, and fastener
penetrations are sealed with KERDI-BAND,
ensuring a minimum 2" (50 mm) overlap.
5
Any protrusions through the panel
(e.g., mixing valve, shower head, etc.)
must be sealed with KERDI-SEAL-PS/-MV,
KERDI-FIX, or other suitable sealant.
6
Seal connections to knee walls using
KERDI-KERECK-F preformed corners and
unmodified thin-set mortar.
7
Grab bars or other heavy objects must be anchored in the structure or solid blocking behind KERDI-BOARD. Installation instructions for other applications
of KERDI-BOARD (e.g. fully embedded or spot-bonded over solid backing) can be found in the 12.1 Schluter
®
-KERDI-BOARD technical data sheet.
Note: See page 21 for KERDI-BOARD-SN
shower niche installation instructions.
KERDI-SEAL-PS/-MV
Once all seams, corners, and knee walls
have been completely sealed, the assembly
is waterproofed and ready to be tiled.
8