To see which units in a rack are available, you can use the “ECHO” command. Each present unit
will respond with its associated slot number (%SN).
The response could be: %01 %03 %08 %10 %11 %12 %15
Note:
Each command must be terminated by a carriage return.
7.2.2 LTU Minirack
For Minirack versions of the LTU, the address number of the DSL interface can be set manually
by monitor commands in the Configuration Management (CM) menu. After power-up of a
Minirack LTU the local monitor main menu appears always with the first DSL system activated
(behaviour like a NTU).
Address numbers in range 1-127 can be set independently to the different DSL systems of a
LTU.
7.2.3 NTU
There is no need of addressing for a point-to-point connection.
For Multipoint Operation see the corresponding chapter