8.6 Monitor Commands for minirack operation
If a plug-in is operated in the Minirack mechanics additional commands are avail-
able in the configuration menu to configure the TMN address of the plug-in.
ADDRESS slot rack
The ADDRESS command allows the user to assign a TMN address to the first
DSL interface of a LTU inserted in the Minirack mechanics.
slot identifies the slot number, rack identifies the rack number. The plug-in will
behave as if it had been inserted in the 19" subrack rack at slot position slot.
LTU_01_CM> ADDRESS 04 01
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Configuration Id : 2 MBit/s G.703
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2 MBit/s
Framing : ITU-T G.704
CRC4 : On
E-Bit Insertion : On
AIS Generation : On
AIS Detection : On
External Clock : Disabled
Data Rate : 31 x 64 = 01984 kbit/s
SHDSL
Master/Slave : Master
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 02048 kbit/s
Operating Mode : 1 Pair
Line Rate : 02056 kbit/s
Remote Powering : On
Regenerators : --
TMN
Address : 04
V.11 wires : 04
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Notes
The CONFIG command always shows the TMN address, not the rack/slot
numbers
RESET command, DEFAULT command and power down have no influence
on settings made for the TMN interface.
Carefully note already used interface address numbers. There is no auto-
matic protection against multiple LTUs assigned to the same interface ad-
dress in a set-up with several Minirack LTUs. Two interfaces with the same
address on the TMN bus will cause addressing conflicts and the units will
not be accessible by remote management
V11WIRES n
The V11WIRES command allows to switch between 2- or 4-wire communication
on the TMN interface.