Specifications

Watson-TDM-Manual-W.doc
Version 2.0-01
Watson TDM
Operating Manual
Revision: 2008-02-07 8-13
If a 1+1 protection group is enabled the user interface of the protection line is
switched off, and the user interface configuration commands are disabled on the
protection line system.
If 1+1 protection is enabled, the LTUMODE display shows the protection group(s):
LTU Mode 1: 4x1p, Local Oscillator, 1+1 Protection
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
System Clk E1 Port SHDSL Port Line Rate Power
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_08: E1 Rx 1 <-------------> 1 (W) 2056 On
: Group_08
LTU_20: :............> 2 (P) 2056 On
LTU_32: E1 Rx 3 <-------------> 3 2056 On
LTU_44: E1 Rx 4 <-------------> 4 2056 On
1+1 protection configuration is shown in the CONFIG display:
Working link:
Local Configuration Id : 2 MBit/s G.703
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2 MBit/s
Framing : Transparent
CRC4 : --
E-Bit Insertion : --
AIS Generation : On
AIS Detection : On
Clock Mode : Local 2Mbit Port
Data Rate : 32 x 64 = 02048 kbit/s
TS Mapping Mode : --
1+1 Protection : Enabled, Working Line, Group_08
SHDSL
Master/Slave : Master
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 04096 kbit/s
Operating Mode : 2 Pair, Local Oscillator
Line Rate : 02056 kbit/s
Remote Powering : On
Regenerators : 1
TMN
Address : 08
V.11 wires : 02
Protection link:
Local Configuration Id : 2 MBit/s G.703
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2 MBit/s
1+1 Protection : Enabled, Protection Line, Group_08
SHDSL
Master/Slave : Master
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 04096 kbit/s
Operating Mode : 2 Pair, Local Oscillator
Line Rate : 02056 kbit/s
Remote Powering : On
Regenerators : 1
TMN
Address : 08
V.11 wires : 02
Note: The GROUP1 and GROUP2 commands are only available on the first system of a