Product data
24
1 2
2
Quantum
™
Ethernet I/O
Ethernet RIO
Ethernet network
Ethernet RIO architecture 
without ConneXium
™
 managed switches
1010
11
References
Modicon
™
 Quantum
™
 Ethernet I/O 
automation platform
Standard Ethernet topologies
References (1)
Ethernet head and drop adaptors (2)
Description Item
(3)
Reference
(4) (5)
Weight 
kg
Ethernet head adaptor
1 adaptor per Quantum
™
 Ethernet I/O CPU rack
Bus current required: 1 A b
SERVICE port: 5 Mbps max., up to 20 Mbps for  b
Ethernet DIO ports
1 140CRP31200 –
Ethernet drop adaptor
1 adaptor per primary rack in each Ethernet RIO drop
Bus current required: 1 A b
SERVICE port: 5 Mbps max., up to 20 Mbps for  b
Ethernet DIO ports
2 140CRA31200 –
Dedicated ConneXium
™
 managed switches (8) (9)
Copper port Multimode ber 
optic port
Single mode 
ber optic port
Item
(3)
Reference
(4) (7)
Weight
kg
RJ45 shielded 
connectors
Duplex SC connectors
8 x 10/100 
BASE-TX ports
– – 5 TCSESM083F23F1 1.000
6 x 10/100 
BASE-TX ports
2 x 10/100 
BASE-FX ports
– 6 TCSESM063F2CU1 1.000
– 2 x 10/100 
BASE-FX ports
6 TCSESM063F2CS1 1.000
Ethernet communication modules and cables (2)
Description Item
(3)
Reference Weight 
kg
Ethernet TCP/IP network 
communication modules
Required if there are Ethernet 
DIO devices in the architecture
Transparent Ready 
class B30
3 140NOE77101 
(4)(6)
0.345
Transparent Ready 
class C30
3 140NOE77111 
(4)(6)
0.345
Ethernet Interlink cables
Required for an architecture with combined 
Ethernet RIO and Ethernet DIO devices.
To be connected between the Ethernet 
140NOE771 p1 communication module 
and the 140CRP31200 head adaptor
Length 1 m
Standard 
version
4 TCSECN3M3M1S4 –
UL version 4 TCSECN3M3M1S4U –
Standard Quantum CPUs
CPU Memory (max.) Item
(3)
Reference
(4) (6)
Weight
Clock 
frequency
RAM Program
(with located 
variables)
Program with  
PCMCIA card
MHz
MB KB KB kg
166 MHz 2 768 7168 7 140CPU65150 –
266 MHz 2 1024 7168 7 140CPU65160 –
4 3072 7168 7 140CPU65260 –
(1) For additional specications, see our website www.schneider-electric.com.
(2) - Requires Unity
™
 Pro Extra Large software u V6.0 (see page 25).
 - Ethernet DIO network: 128 Ethernet DIO devices max.
(3) For items 8 to 11, see page 25.
(4)  Conformal Coating version available for harsh environments with the application of Humiseal 
1A33. In this case, add the letter “C” to the end of the reference.
(5)  Certications (1): e, CEI/EN 61131-2, UL 508, CSA 22.2 No. 142, CSA 22.2 No. 213 
(Haz Loc Class I Div 2), EtherNet/IP (by ODVA).
(6) Certications (1): e, UL 508, CSA 22.2 No. 142, cUL, FM Class 1 Div. 2.
(7)  Certications (1): e, IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, 
CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), GL, C-Tick, LR, BV.
(8) ConneXium managed switches validated for Quantum Ethernet I/O architectures.
(9) Predened conguration les included on Unity Pro u V6.0 DVD.
Managed 
switch
Architecture with combined Ethernet RIO and Ethernet DIO 
devices
Quantum 
Ethernet I/O
Ethernet RIO
Ethernet DIO device cloud (2)
Ethernet network
3
47
5
1
2
2 2
7