Technical information
3/30
Presentation
Modicon M580 automation 
platform
Probus DP V1 and Probus PA buses
Probus Remote Master module
Probus DP eldbus
Probus DP is one of the most widely used eldbuses in industry.  Based on a 
master/slave protocol, only master stations, sometimes called active stations, have 
the right to access the bus, with slave, or passive, stations being limited to 
responding to interrogations. 
Version V0 of Probus only allows cyclic exchanges with I/O, whereas version V1 
offers an acyclic message handling channel that can be used for device adjustment 
or diagnostics during operation.
The physical link is a single shielded twisted pair, but numerous interfaces are 
available for creating all sorts of topologies - tree, star, or ring - including those using 
optical ber or a non-physical link.
Gateways can be used to communicate transparently with Probus PA, one of the 
most commonly used standards in process applications for connecting 
instrumentation. Probus PA can be used to supply devices across the network and 
also to install sensors in potentially explosive zones (ATEX).
Unity Pro
PRM master
PRM Com DTM
Ethernet
Probus PA
PRM
Probus DP
DP Class 1
Probus Remote Master (PRM) module
Presentation
The Probus Remote Master (PRM) module is connected to the Ethernet Modbus 
TCP/IP network via its integrated 2-port switch, as close as possible to the process 
and the instrumentation. 
The PRM module can be used to connect Modicon Quantum, Premium, M580, and 
M340 PLCs to Probus DP V1 via the I/O scanner function. 
Irrespective of the type of PLC, only one product reference is required and setup is 
identical, thus reducing training and maintenance costs. 
Two versions are available, standard and tropicalized, so as to adapt to any type of 
environment.
The PRM module is open to Asset Management tools. A dedicated communication 
DTM is supplied with the product, thus allowing any compatible FDT standard tool to 
remotely adjust devices on Probus using Ethernet.
Conguration
From a single Unity tool, the user can create the Probus conguration, the PLC 
application, and congure or calibrate devices. 
The latter are integrated in the Unity catalog via their DTMs if they exist, or their gsd
les.
The I/O scanner conguration is created implicitly in Unity Pro using the Probus 
conguration. The parameters assigned by default help optimize performance, as well 
as the consistency of I/O data in the PLC application, irrespective of the PLC 
platform.
Similarly, the I/O variables dened and presymbolized in the DTMs can be used 
directly in the application. Finally, the screens integrated in Unity Pro, together with 
the diagnostic functions integrated in the device DTMs simplify application 
maintenance.