Transferring Data Using Communication Blocks
148
33002479 06 07/2008
Representation 
in FBD
Representation 
in LD
Note: To prevent the former standby CPU, which has switched its state for RUN 
offline from executing communication functions, you must add a condition on the 
status bits to disable the function, if the CPU is offline.
Note: Several copies of this function block can be used in the program. However, 
multiple instancing of these copies is not possible.
OperationActiv
MBP_MSTR
EnableMSTRFunction
CancelActivMSTROperation
FaultyOperation
OperationSuccessful
ControlBlock
DataField
MBP_MSTR_Instance
ACTIVE
ERROR
SUCCESS
CONTROL
DATABUF
ENABLE
ABORT
CancelActivMSTROperation
EnableMSTRFunction
ENOEN
OperationActiv
MBP_MSTR
FaultyOperation
OperationSuccessful
ACTIVE
ERROR
SUCCESS
DATABUF
ENABLE
ABORT
MBP_MSTR_Instance
DataField
CONTROL
ControlBlock