User Manual

Table Of Contents
DI[D-SE-0029857.1.5] Specifications and Physical Description
EIO0000001601 Draft 2013/07/17 29
Connecting the OsiSense X G Smart Antenna
Connecting the OsiSense XG Smart Antenna
Introduction
The Smart Antenna is equipped with:
a male M8 connector for the power supply,
2 female M12 D-coded connectors for Ethernet communication.
Power Supply Wiring
The table describes the M8 connector pinout:
NOTE: Use a PELV power supply and fuse protection (1 A). The power supply used must be class
II according to VDE 0106 (for example: Phaseo ABL 7/8 range of Schneider Electric). The 0 V must
be connected to the ground to increase EMC strength.
Communication Wiring
The table describes the M12 connectors pinout a
nd the correspondence with the RJ45 connector
of communication cables (seepage30):
M8 Connector Pin No. Signal XZCP0941L• Wire Color
1
+24 V
Brown
2 Not connected White
3
0V
Blue
4 Not connected Black
M12 Connector M12 Pin Signal Description RJ45 Pin RJ45 Connector
1 TD+ Transmit Data + 1
2 RD+ Received Data + 2
3 TD– Transmit Data – 3
4 RD– Received Data – 6
- - Not connected 4
- - Not connected 6
- - Not connected 7
- - Not connected 8