Operating Principles DI[D-SE-0029865.1.1]
50 EIO0000001601 Draft 2013/07/17
Objects 8002h...8009h
UID:
Each tag has a different single code (UID). This code is distributed in 16 bytes.
Object 8018h
Smart Antenna address:
Reading request:
Response to the reading request:
Writing request:
MSB LSB
Updated each time there is a new tag and valid if tag present.
MSB LSB
0 Smart Antenna address
Writing Request Result
MSB LSB
0...1E Smart Antenna address No action
1F Smart Antenna address The new Smart Antenna address is effective
immediately.