Mounting the InsightFacility
DIN Rail Mount
To mount the InsightFacility on the DIN Rail:
1. Use a standard 35-mm “top hat” DIN rail (EN50022).
2. You may choose to move the mounting clip to the side as shown.
3. Attach the device to the DIN rail. Hook the bottom catch of the clip onto the rail, pull
up a little to retract the bottom catch and hook the top catch of the clip onto the rail.
4. Connect the wiring and cables.
Connecting the InsightFacility to the Xanbus Network
To connect the InsightFacility to the Xanbus network:
1. Connect the InsightFacility to the Xanbus network using daisy chain confguration.
a. Xanbus components can be arranged in any order.
b. The left connectors are Xanbus 1 and the right connectors are Xanbus 2.
c. Do not connect two end devices together to form a closed loop configuration.
2. Use a network terminator at both ends of the network. See Figure 7 .
a. Both networks require two Xanbus terminations; Xanbus 1 and Xanbus 2, if
the second network is used. Xanbus 2 does not need terminators if it is not
used.
3. Do not interconnect two separate Xanbus networks, meaning, do not daisy chain one
Xanbus network with another.
a. Not intended to be used in two separate inverter systems.
b. Use only one pair of Xanbus ports for the daisy chain.
c. If you only have one Xanbus network use Xanbus 1.