InsightFacility Manual

Table Of Contents
Electrical Specifications
NOTE: Specifications subject to change without prior notice.
NOTICE
EQUIPMENT DAMAGE
Do not power the unit without first installing the supplied antennas.
Failure to follow these instructions can result in equipment damage.
Power Consumption 2 W average / 10 W peak
AC/DC adapter Input: 100-240 V AC, 50-60 Hz, 0.48 A,
Output: 12 V DC, 1.6 A, 5.5 mm outer, 2.1 mm center-
positive jack.
NOTE: Required when used with the Conext SW.
Xanbus When connected to Conext XW Pro/XW+ or
MPPT 80 600 providing network power
9–24V on 26-pin connector 9–24 V DC, 1 A max input only through pins 1 and 2
Accepts 1624 AWG pin wire size, wire length should
meet local regulations
Operation Frequency 24122472 MHz (Europe)
24142462 MHz (N. America)
Max. radio frequency power
transmitted
17.06 dBm (E.I.R.P., Declaration for EU)
Physical Specifications
NOTE: Specifications subject to change without prior notice.
Weight (device only) 330 g (0.73 lb)
Dimensions (device only)
(W × H × D)
138 x 135 x 41mm (5.4 × 5.3 × 1.6inches)
Shipping package dimensions 193 × 161 × 105mm (7.6 × 6.3 × 4.1inches)
Shipping package weight 800 g (1.7 lbs)
Housing/Mounting system ABS Plastic / 35-mm DIN rail clip
IP rating / Mounting Location IP 20, NEMA 1, Indoor only
Status Display 3 x LEDs
Temperature Operating: -4 to 122 °F (-20 to 50 °C) Storage: -40
to 185 °F (-40 to 85 °C) Maximum case
temperature: 140 °F (60 °C)
Humidity Operating: < 95%, non-condensing Storage: < 95%
InsightFacility Owner's Guide Specifications
73 990-91411A