Schneider Electric XW+ PDP Installation Manual

975-0735-01-01 Revision B
05-2015
Add UL/CSA approved strain relief
clamps to knockout holes.
Add UL/CSA approved strain relief
clamps to knockout holes.
NOTE: All wires, cables, and breakers in this
illustration are not provided with the Mini PDP.
See section B Materials List for information on DC
breakers.
5
solar.schneider-electric.com
Conext Mini Power Distribution Panel Installation Guide
865-1013-01
NOTE: All wires, cables, and breakers in this
illustration are not provided with the Mini PDP.
See section B Materials List for information on DC
breakers.
Connecting PV Inverter AC wires to a fourth AC breaker and to the Bypass terminals Connecting DC cables from the PV breaker to the MPPT 60 150 and to the PV array
Install a fourth AC breaker
(not provided) in the
highlighted slot.
Connect L1 and L2 wire
ends to the breaker output
terminals.
Connect L1 and L2 wire
ends to the breaker input
terminals.
Connect L1 and L2 wire
ends to the bypass termi-
nals.
Connect L1 and L2 wire ends
to the PV Inverter’s AC OUT
terminals.
PV INVERTER
CONNECTION ONLY
DC+ DC–
BYPASSAC
DC+ DC–
BYPASS
Install the battery breaker
(not provided) as shown in
the highlighted slot.
Install the PV breaker (not
provided) as shown in the
highlighted slot.
Install a DC cable (#4)
between the battery
breaker’s out terminal
and the Mini PDP’s
battery (+) lug.
Connect the end of a DC
cable (#3) to the PV
breaker’s out terminal.
Route the DC cables
through a knockout and
connect them to their
proper terminals.
Connect the end of a DC
cable (#1) to the battery
breaker’s in terminal.
Connect the end of a DC
cable (#2) to the PV
breaker’s in terminal.
MPPT 60 150 Battery (+)
MPPT 60 150 PV (+)
PV Array PV (+)
(2nd pair)
(1st pair)