Instruction Manual

Table Of Contents
Mechanical Specifications
975-0400-01-01 Revision H A–3
This manual is for use by qualified personnel only.
Mechanical Specifications
Output Power Versus Ambient Temperature
Once the charge controller heat sink reaches maximum full-power operating
temperature, the unit reduces its power output to ensure component ratings are
not exceeded.
Enclosure Type Indoor, ventilated, sheet metal chassis with " and 1"
(22.22 mm and 27.76 mm) knockouts and aluminum
heat sink
Maximum and
Minimum Wire Size in
Conduit
#6 AWG to #14 AWG (16 to 2.5 mm
2
)
Maximum and
Minimum Wire Size
Rating of Terminal
Block
#3 AWG to #14 AWG (25 to 2.5 mm
2
)
Operating Temperature
Range (full power)
-4 to 113°F (-20 to +45°C)
Storage Temperature -40 to 185°F (-40 to +85°C)
Pollution degree 2
Over voltage category CAT II
Altitude Limit
(operating)
Sea level to 6,500 feet (approximately 2000 m)
Dimensions (H × W ×
D)
14 ½ × 5 ¾ × 5 ½" (368 × 146 × 138 mm)
Mounting Vertical wall mount
Weight (Controller only) 10.75 lb (4.8 kg)
Weight (Shipping) 13.75 lb (6.2 kg)
7
8
---
Figure A-1 Output Power vs. Ambient Temperature
Pout (kW)
Ambient Temp (°C)
in Still Air
-20 -10 0 10 20 30 40 50 60 70
0.5
1.0
1.5
2.0
2.5
3.0
3.5
45