Owner's Guide

Table Of Contents
WARNING
HAZARD OF FIRE AND EXPLOSION
Do not use the Copy from command to copy settings unless the battery banks are
identical the same size, type, and so on.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
SCP
Menu
Item
Setting Values Default Description
Advanced
Settings
Copy
from
All other
similar Xanbus
connected
devices
01
Enables one-step configuration of a new charge controller in a multi-unit
installation. Select the device number of the charge controller from which you
want to copy the setup. This screen is hidden when no compatible devices
are found.
The Copy from command copies all charger settings and custom battery
settings from the selected charge controller.
Table 8Advanced settings
Note:
The Copy from command will not give you any indication that it has completed its task. To check that the charger
settings have been copied properly, view some of the settings you originally configured.
Settings that are copied from one charge controller to another are:
n
Batt Type
n
Batt Capacity
n
Max Chg Rate
n
Charge Cycle
n
ReCharge Volts
n
Absorb Time
n
Default Batt Temp
n
Batt Voltage
n
DC Conn
n Custom battery settings (if Custom battery type selected) including Eqlz Support, Eqlz Voltage,
Bulk Voltage, Absorb Voltage, Float Voltage, and BattTempComp.
Conext MPPT 80 and Conext MPPT 100 Owner’s Guide Configuration
41 This document is for use by qualified personnel 990-6214