Mechanical Specifications
Enclosure Type
IP20, indoor, ventilated, aluminum sheet metal chassis with 7/8" and 1" (22.22 mm
and 27.76 mm) knockouts and aluminum heat sink
Maximum and Minimum Wire Size in
Conduit
#6 AWG to #14 AWG (13.5 to 2.5 mm
2
)
Maximum and Minimum Wire Size
Rating of PV Terminal Block
#6 AWG to #14 AWG (13.5 to 2.5 mm
2
)
Maximum and Minimum Wire Size
Rating of Battery Terminal Block
#2 AWG to #14 AWG (35 to 2.5 mm
2
)
Wire Size Rating of Auxiliary Output
Connector
#16 AWG (1.5 mm
2
)
Operating Temperature Range
-20 to +65°C (-4 to 149°F)
(derate above 40°C, see Figure 12)
Storage Temperature -40 to +85°C (-40 to 185°F)
Pollution degree 2
Over voltage category CAT II
Altitude Limit (operating) Sea level to 6,500 feet (approximately 2000 m) recommended
Unit Dimensions (H × W × D) 30 × 8 5/8 × 8 5/8" (760 × 220 × 220 mm)
Mounting Vertical wall mount
Weight (charge controller only) 29.8 lb (13.5 kg)
Weight (shipping) 45 lb (20.4 kg)
Table 21Mechanical specifications
Conext MPPT 80 and Conext MPPT 100 Owner’s Guide Specifications
68 This document is for use by qualified personnel 990-6214