Conext SW 4024-120 Install Guide
Table Of Contents
- Conext™ SW Inverter/Charger
- Exclusion for Documentation
- Document Number: 975-0639-01-03 Revision: Date: 5-2020
- Contact Information solar.schneider-electric.com
- Information About Your System
- About This Guide
- Important Safety Instructions
- Safety Information
- Precautions When Working With Batteries
- FCC Information to the User
- Installation
- Materials List
- Conext SW Front and Side Panels
- Conext SW Supplied Accessories
- Conext SW Required Accessory
- Installation Information
- Before You Begin the Installation
- Installation Codes
- Xanbus Network System
- Xanbus System
- Xanbus-enabled Products and Other Accessories
- Installation Planning
- Planning Preparations
- Components of the Inverter Power System
- Unpacking and Inspecting the Conext SW Inverter/Charger
- Installation Tools and Materials
- Inverter/Charger Installation
- Overview
- Step 1: Choosing a Location for the Inverter/Charger
- Step 2: Mounting the Inverter/Charger
- Step 3: Connecting the AC Input and AC Output Wires
- AC System Bonding
- Step 4: Installing the DC Switchgear and Connecting the DC Cables
- Step 5: Connecting the BTS and Xanbus-enabled Components
- Step 6: Performing Checks Prior to Initial Start-Up
- Step 7: Testing Your Installation
- Battery Information
- Battery Bank Sizing
- Estimating Battery Requirements
- Restrictions on Motor Size
- Battery Cabling and Hook-up Configurations
- Specifications
- Inverter Specifications
- Charger Specifications
- AC Transfer Specifications
- Physical Specifications
- Environmental Specifications
- Regulatory
- Wiring Diagrams
- Single-Inverter System (Off-Grid/Power Backup)
- Single-Inverter System Renewable Energy (Solar)
Inverter/Charger Installation
975-0639-01-03 1–21
This guide for use by qualified personnel only
Figure 1-10 Conext SW Mounting Instructions
5
7/8
in.
149.0 mm
(1) Place the
installation bracket flat
on non-flammable wall
(see page 1–19 for
definition) and mark
the positions of the
mounting holes on the
wall.
(2) Pilot drill the four
mounting holes on the
wall. Install the
appropriate anchors.
(3) Fasten the
installation bracket to
the mounting surface
with four #12 (or
equivalent) screws (or
bolts).
(4) With two people,
hang the Conext SW to
the installation bracket
carefully aligning the
Conext SW’s mounting
holes to the threaded
bolts on the installation
bracket.
(5) Secure the Conext
SW to the installation
bracket using the
supplied M6 nuts.
(2)
TIP: Use these
mounting holes.
NOTE: These mounting instructions are general guidelines and are provided here for information purposes only.
You must install with care and heed precautions and warnings as stated beginning in “Step 1: Choosing a
Location for the Inverter/Charger” on page 1–19 and all subsequent steps.